Technical data
Type S020
Table 21: K factors, external diameters and theoretical cross-sections of welding sockets with radius and fusion spigots, in plastic, used with a
8041 or a 8045 with G2'' nut
Measuring
device inserted
8041, 8045 with sensor in
stainless steel
8041, 8045 with sensor in PVDF
External diameters and theoretical
cross-sections
Material of the
pipe
Stainless
steel
PE / PP PVDF
Stainless
steel
PE / PP PVDF
D
steel
[mm]
s
steel
[mm]
D
PE/PP
[mm]
s
PE/PP
[mm]
D
PVDF
[mm]
s
PVDF
[mm]
DN
50 11,6 (C) - - 13,8 (C) - - 60,3 2,0 - - - -
65 20,0 (C) 17,8 (C) 24,1 (C) 24,0 (C) 21,3 (C) 28,9 (C) 76,1 2,9 75 6,9 75 2,5
80 28,5 (C) 25,6 (C) 40,8 (C) 33,2 (C) 30,7 (C) 48,9 (C) 88,9 3,2 90 8,2 90 2,8
100 49,2 (C) 38,1 (C) 70,5 (C) 60,5 (C) 45,7 (C) 84,5 (C) 114,3 3,6 110 10 110 3,5
110 - - - - - - - - - - - -
125 78,0 (C) 81,7 (L) - 93,6 (C) 81,7 (L) - 139,7 4 140 12,8 - -
150 98,4 (C) 103 (L) - 118 (C) 103 (L) - 168,3 4,5 160 14,6 - -
180 - - - - - - - - 200 18,2 - -
200 210 (C) 224 (L) - 252 (C) 224 (L) - 219,1 6,3 225 20,5 - -
250 311 (L) 347 (L) - 311 (L) 347 (L) - 273 7,7 280 25,5 - -
300 447 (L) 510 (L) - 447 (L) 510 (L) - 323,9 9,5 315 28,7 - -
350 609 (L) 705 (L) - 609 (L) 705 (L) - 355,6 10,1 355 32,3 - -
400 - 931 (L) - - 931 (L) - - - 400 36,4 - -
(C): short sensor version
(L): long sensor version
English