Specifications
50
APPENDIX I – IQ Control System (continued)
IQ Outdoor Reset Option Card: P/N 102723-01 
Installing the IQ Outdoor Reset Option Card is the simplest way to maximize 
the efciency of any boiler. The IQ Outdoor Reset Card is a microprocessor-
based  control  that  regulates  the  water  temperature  of  the  heating  system 
based on the outdoor temperature. By modulating the water temperature of 
the heating system, the boiler equipped with an IQ Outdoor Reset Option Card 
will deliver annual fuel savings up to 16%, while increasing home comfort. The 
IQ Outdoor Reset Option Card is simple to set up yet it includes a powerful list 
of features that can be customized for any job.
IQ Oil Boiler Control Operating Setpoint is normally set to the High Limit Setpoint. However, when an IQ 
Outdoor Reset Option Card is installed the Operating Setpoint may be reduced to the outdoor reset or 
Domestic Hot Water (DHW) Setpoint. When an IQ Outdoor Reset Option Card is added the following user 
dened setpoints are available:
•  High Limit Setpoint - The High Limit becomes the upper limit for the operating setpoint. The 
operating setpoint can not be set higher than this value. The High Limit is set to protect the boiler 
and hydronic system from excessive temperature.
•  DHW Setpoint - The Operating Setpoint is set to the DHW Setpoint when the Control or Outdoor 
Reset Option Card DHW input is energized. This setpoint is set equal to the Indirect Water Heater 
manufacturer's recommended water temperature.
•  High Boiler Water Temperature - The High Boiler Water Temperature (also known as the "Boiler 
Water Design Temperature") setpoint is set to the lowest boiler water temperature that will heat 
the home on the home's design day. This adjustment typically depends on the type and quantity 
radiation (heating element) installed in the home.
Major Features:
• Selectable DHWP
• Selectable/adjustable DHWP protection
• Selectable/adjustable boost feature
• Simple adjustment of reset curve
Kit Includes:
• IQ Outdoor Reset Option Card
• Outdoor temperature sensor w/mounting bracket & 60” lead
• Instructions
IQ LWCO Option Card (Auto Reset): P/N 102711-01
IQ LWCO Option Card (Manual Reset): P/N 102714-01
IQ  LWCO  Option  Cards  add  a  low  water  cut-off  function  to  boilers.  LWCO 
Option Cards plug into the IQ Option Panel and connect to the system-mounted 
sensor with a single-wire connection.  IQ LWCO Option Cards feature built-in 
diagnostics, probe  signal strength  display, and include  a “Test”  and “Reset” 
feature in compliance with UL 353 and CSA 22.2 for CSD-1 Compliance in US 
and Canada.
Kit Includes:
• IQ LWCO Option Card
• 3/4” NPT level sensor
• 36” wire sensor connector
• Instructions
Major Features:
• UL 353 approved
• Displays signal strength
• Warns when probe cleaning required