SECTION 3.0 WATER PIPING (continued)
Fig. 3 — 11 Net Expansion Factors for Water ...............................................46
— 12 Acceptance Factors for Diaphragm Type Tanks ........................47
— 13 Module Data-Water Side ...........................................................47
— 14 Water Piping for Service Water Heater ......................................48
— 15 Service Hot Water Demand, Fixture Units ................................. 49
— 16 Service Hot Water Flow Rate ....................................................49
— 17 Sizing Factors for Combination Heating/Service Water .............50
SECTION 4.0 GAS PIPING .................................................................................. 51
Fig. 4 — 1, 2 Recommended Gas Supply Piping ................................... 54 & 55
— 3 Gas Pipe Sizing Table ...............................................................56
— 4 Equivalent Length of Fitting & Valves — Gas Pipe .................... 56
— 5 Maximum Capacity of Pipe ........................................................57
—6 CorrectionFactorsforSpecicGravity ......................................57
— 7 Support of Piping .......................................................................58
— 8 Moisture and Dirt Trap ...............................................................58
SECTION 5.0 CONTROLS .................................................................................. 59
Fig. 5 — 1 Tekmar 261, Two-Stage, EI, for Parallel Piping .........................61
— 2 Tekmar 261, Two-Stage, EI, for Primary Secondary Piping ......62
— 3 Tekmar 263, Two-Stage, EI, for Parallel Piping .........................63
— 4 Tekmar 263, Two-Stage, EI, for Primary Secondary Piping ......64
— 5 Tekmar 274, Two-Stage, EI, for Parallel Piping .........................65
— 6 Tekmar 274, Two-Stage, EI, for Primary Secondary Piping ......66
— 7 Tekmar 268, Two-Stage, EI, for Parallel Piping .........................67
— 8 Tekmar 268, Two-Stage, EI, for Primary Secondary Piping ......68
SECTION 6.0 START-UP AND SERVICE ............................................................ 69
Series 8H/8HE Boilers are NOT suitable for direct installation on combustible ooring.
Refer to the 8H/8HE Installation, Operating and Service Instructions (Part Number 81416021) for Installation
Instructions for Floor Shields that are available and required for combustible oor installations.
LIST OF FIGURES (continued)
PAGE