XIII. Service and Maintenance
Important Product Safety Information
Refractory Ceramic Fiber Product
WARNING
The Service Parts list designates parts that contain refractory ceramic bers (RCF). RCF has been classied
as a possible human carcinogen. When exposed to temperatures above 1805°F, such as during direct ame
contact, RCF changes into crystalline silica, a known carcinogen. When disturbed as a result of servicing, these
substances become airborne and, if inhaled, may be hazardous to your health.
AVOID Breathing Fiber Particulates and Dust
Precautionary Measures:
Do not remove or replace RCF parts or attempt any service work involving RCF without
wearing the following protective gear:
1. A National Institute for Occupational Safety and Health (NIOSH) approved
respirator
2. Long sleeved, loose tting clothing
3. Gloves
4. Eye Protection
Take steps to assure adequate ventilation.
Wash all exposed body areas gently with soap and water after contact.
Wash work clothes separately from other laundry and rinse washing machine after
use to avoid contaminating other clothes.
Discard used RCF components by sealing in an airtight plastic bag. RCF and
crystalline silica are not classied as hazardous wastes in the United States and
Canada.
First Aid Procedures:
If contact with eyes: Flush with water for at least 15 minutes. Seek immediate
medical attention if irritation persists.
If contact with skin: Wash affected area gently with soap and water. Seek
immediate medical attention if irritation persists.
If breathing difculty develops: Leave the area and move to a location with
clean fresh air. Seek immediate medical attention if breathing difculties
persist.
Ingestion: Do not induce vomiting. Drink plenty of water. Seek immediate