Install Instructions

5
TABLE 1A: DIMENSIONAL DATA (SEE FIGURES 1A THRU 1D)
TABLE 1B: RATING DATA
Boiler Model
No.
Dimensions
See Figures 1A thru 1D
Water Content - Gallons
Heat Transfer
Surface Area -
Sq. Ft.
Approximate
Shipping Weight
(LB.)
"A" "B" "C" Steam Boiler
Water
Boiler
Water
Boiler
Steam
Boiler
V8H3 17-1/8" 9-1/8" 6" 10.3 12.8 15.88 542
V8H4 22-1/8" 11-5/8" 6" 12.4 15.7 22.92 634
V8H5 27-1/8" 14-1/8" 7" 14.6 18.5 29.96 726
V8H6 32-1/8" 16-5/8" 7" 16.7 21.4 37.00 818
V8H7 37-1/8" 19-1/8" 8" 18.8 24.2 44.04 910
V8H8 42-1/8" 21-5/8" 8" 20.9 27.1 51.08 1002
V8H9 47-1/8" 24-1/8" 8" 23.0 30.0 58.12 1094
NOTE: 1 Maximum working Pressure: Steam: 15 PSI; Water: 30 PSI Shipped From Factory (Std.),
40 PSI Optional, 50 PSI Optional
Boiler
Model No.
*
Burner Capacity I=B=R NET Ratings
AFUE %
(Thermal Effy.)
Minimum Chimney
Requirements
GPH MBH
DOE Heating
Capacity MBH
Water
MBH
Steam
MBH
Steam
Sq. Ft.
Steam Water
Round
In. Dia.
Rectangle
In. x In.
Height
Ft.
V8H3S 0.75 1.05 91 68 283 85.1 6 8 x 8 15
V8H3W 1.05 147 125 109 85.0 6 8 x 8 15
V8H4S 1.05 147 127 95 396 85.3 6 8 x 8 15
V8H4W 1.35 189 162 141 85.3 7 8 x 8 15
V8H5S 1.35 189 164 123 512 85.4 7 8 x 8 15
V8H5W 1.65 231 198 172 85.3 7 8 x 8 15
V8H6S 1.65 231 201 151 629 85.7 7 8 x 8 15
V8H6W 1.90 266 228 198 85.3 8 8 x 8 15
V8H7S
V8H7W
2.10 294 252 219 189 787 84.7 85.0 8 8 x 8 15
V8H8S 2.35 329 266 200 833 (81.4) 8 8 x 12 15
V8H8W 2.35 329 275 239 (82.0) 8 8 x 12 15
V8H9S 2.60 364 298 224 933 (82.3) 9 8 x 12 15
V8H9W 2.60 364 299 260 (82.3) 9 8 x 12 15
* Boiler Model Sufx: S=Steam, W=Water
SECTION I: PRODUCT DESCRIPTION, SPECIFICATION
AND DIMENSIONAL DATA
The V8H Series boiler is a cast iron oil-red water boiler
designed for closed forced circulation heating systems or a
low pressure steam boiler designed for use in closed heating
steam systems. This boiler must be vented by natural draft
into a reclay tile-lined masonry chimney or chimney
constructed from type L vent or a factory built chimney
that complies with the type HT requirements of UL03. An
adequate supply of air for combustion, ventilation and
dilution of ue gases must be available in the boiler room.
Water Boilers
The V8H Series water boiler uses an Intelligent Oil
Boiler Control (boiler control). The boiler control
replaces the traditional electronic aquastat and
circulator relays and adds energy saving thermal purge
features. Energy is saved by starting the circulator and
delaying the burner start when there is residual heat
available in the boiler. A Warm Start Intelligent Oil
Boiler Control (Warm Start Boiler Control) is included
with a tankless heater option to generate domestic hot
water.
Steam Boilers
The V8H Series steam boiler uses a L404F Pressure
Limit and Low Water Cut-off. This boiler has indirect
domestic water heater connections to generate domestic
hot water. Optionally, this boiler may include a L4006
Temperature Limit and a tankless heater to generate
domestic hot water.