Product Overview

© 2016 U.S. Boiler Company, Inc. - Lancaster, PA
Phone: 1-888-432-8887
Printed in the U.S.A.
Form No. HYDL07084-10Ms
Independence PV Ratings & Specications (Natural Gas, Packaged)
Boiler
Model
Input
MBH
DOE
Heating
Capacity
MBH (1)
I=B=R Net
Ratings
Maximum
Vent Length
Equivalent
Ft. (2) (3) AFUE%
Approx
Shipping
Weight
(LBS.)
Steam
MBH
Steam
Sq. Ft.
IN3PVNI 62 52 39 163 45 83.2 355
IN4PVNI 105 87 65 271 35 82.2 425
IN5PVNI 140 116 87 363 35 82.2 490
IN6PVNI 175 145 109 454 35 82.2 560
1. Capacities and ratings are based on steam combustion efficiency of 83.0%.
(84.1% for PIN3PV)
2. The approved venting system for the Independence PV is 3” AL29-4C
®
stainless steel. Do not
substitute other materials.
3. Vent pipe length is listed in equivalent feet. Any elbows or tees used can have specific values
which must be subtracted from the total length to determine maximum length of straight pipe.
Consult Installation, Operating, and Service Instructions for details.
Dimensions
Boiler
Model
A B C D E F G
IN3I 14-1/2 40 33-3/4 4 40-1/4 4-3/4 7-1/4
IN4I 17-3/4 40 34-3/4 5 40-1/4 4-3/4 8-7/8
IN5I 21 40 35-3/4 6 40-1/4 5-1/4 10-1/2
IN6I 24-1/4 40 35-3/4 6* 40-1/4 5-1/4* 12-1/8*
IN7I 27-1/2 40 36-3/4 7 40-1/4 7-1/2 13-3/4
IN8I 30-3/4 40 36-3/4 7* 40-1/4 7-1/2* 15-3/8*
IN9I 34 40 37-3/4 8 40-1/4 7-1/2 17
IN10I 37-1/4 45 38-3/4 8* 45-1/2 7-1/2 18-5/8
IN11I 40-1/2 45 38-3/4 9 45-1/2 7-1/2 20-1/4
IN12I 43-3/4 45 38-3/4 9 45-1/2 7-1/2 21-7/8
IN3PVNI 14-1/2 45 N/A 3 N/A N/A 4
IN4PVNI 17-3/4 45 N/A 3 N/A N/A 8-1/4
IN5PVNI 21 45 N/A 3 N/A N/A 9-1/4
IN6PVNI 24-1/4 45 N/A 3 N/A N/A 9-1/4
www.usboiler.net
Standard Equipment
(Semi Pack & K/D):
• Sectionassembly
• Insulateddeluxejacket
• Base-burnermanifoldassy.
• Flameroll-outswitch(FRS)
• Gascontrolassembly
• Canopy
• Reardrafthood
• Blockedventswitch
• Ventdamper
Packaged Boilers add:
• Pressurelimit
• 24Vtransformer
• ProbetypeLWCO
• Junctionbox
• Thermostatisolatingrelay
• Electronicignitionassembly
• 15PSIsafetyvalve
• Steamgauge
• Gaugeglass
• 3/4”drainvalve
• Wiringharness
PV Boilers add (in lieu of
chimney venting equipment):
• Induceddraftfan
• Suctionpressureswitch
• Thermostatblowerrelay
• Ventaccessorycarton:vent
connector with locking band,
vent terminal, clamp
• 3oz.tube,siliconesealant
A
S
M
E
H
Independence Ratings & Specications*
Model*
Input
MBH
(1)
DOE Heating
Capacity
I=B=R Rating (2)
AFUE
Approx
Shipping
Weight (Lbs.)
Minimum Chimney
Requirements
(Round) Dia.
(In.) x Ht. (Ft.) (4) (5)
Water
MBH
Steam
MBH
Steam
Sq. Ft.
IN3I 62 51 44 38 158 81.9 350 4x15
IN4I 105 87 76 65 271 82.0 420 5x15
IN5I 140 115 100 86 358 82.0 485 6x15
IN6I 175 144 125 108 450 82.1 555 6x15(5)
IN7I 210 173 150 130 542 82.1 620 7x15
IN8I 245 202 176 152 633 82.1 690 7x15(5)
IN9I 280 231 201 173 725 82.2 760 8x15
Gross Output
MBH
Combustion
Efciency
IN10(3) 315 260 226 195 812 79.5 815 8 x15(5)
IN11(3) 349 288 250 216 900 79.5 885 9x15
IN12 385 318 276 239 996 79.5 815 9x15
*LP available on IN3-IN9
1. Ratingsshownareforinstallationsatsealevelandelevationsupto2,000ft.Forhigherelevations,reduceratings4%foreach1,000ft.abovesealevel
2. Capacities, outputs, and ratings are based on steam combustion efficiency of 82.5%.
3. For Canadian builds only: reduce input and output by 3%
4. 15 ft. height is measured from top of drafthood to top of chimney.
5. IN6, IN8, & IN10 – Canada only: Increase chimney
diameter by 1”
MaxWorkingPressure:15PSISteam