Manual

10
LP GAS CONNECTION
The refrigerator is designed for operation on LP gas, the pressure of which must be 2.75kPa for Propane
Check that this is stated on the dataplate. The refrigerator is NOT designed for operation on town gas or
natural gas.
CAUTION! CHECK THAT THE GAS SUPPLIED TO THE REFRIGERATOR IS AT THE PROPER
PRESSURE. SEE THE PRESSURE REGULATOR ON THE LP GAS CONTAINER.
This appliance shall be installed only by authorised persons and in accordance with the manufacturer's
installation instructions, local gas fitting regulations, municipal building codes, AS/NZS 5601 - Gas
Installations and any other statutory regulations.
The gas supply pipe should be connected to the gas inlet of the gas control valve by means of a suitable
threaded coupling.
In making the connection to the refrigerator, a union gas cock of an approved bottled-gas type must be
incorporated in the supply line in a position which is readily accessible to the user. For eventual servicing
purposes, the union should be on the outlet side of the cock and the pipework should be positioned so as not
to prevent the refrigerator from being readily withdrawn.
AN APPROVED MANUAL SHUT-OFF VALVE MUST BE INSTALLED AT THE GAS INLET OF THE
REFRIGERATOR. THE SHUT-OFF VALVE MUST BE ACCESSIBLE TO THE USER WHEN THE
APPLIANCE IS IN THE INSTALLED POSITION.
BEFORE LEAVING –Check all connections for gas leaks with soap and water. DO NOT use a naked flame
for detecting leaks. Ignite the burner to ensure correct operation of gas valve, burner and ignition. Turn gas
tap to low flame position and observe stability of the flame. When satisfied, please instruct the user on the
correct method of operation. In case the appliance fails to operate correctly after all checks have been carried
out, refer to the authorised service provider in your area.
230V AC connection.
Check that the voltage stated on the data plate is the same as the mains voltage in use (230 V).
Plug the 230 V refrigerator power cord into an easily accessible earthed wall socket.
Electrical leads must be routed and secured so that they cannot come into contact with hot or sharp
parts of the refrigerator.
12 V DC connection.
For 3 ways model, there is a terminal block in the rear bottom for 12VDC. You can ignore the positive and
negative indication, simply connect the 12V DV power to the two terminals.