Manual

11
OPERATION INSTRUCTIONS Model XCD-100
PUSH WHEN LIGHTING
OFF / ON
Fig1 A B C D
After initial installation, servicing, or changing gas cylinders etc., the gas pipes may contain some air which
should be allowed to escape by briefly turning on the refrigerator. This will ensure that the flame lights
immediately.
1. Make sure that all valves between the gas container and the refrigerator are open.
2. Depress the safety device control (C) and hold it down while depressing the piezoelectric igniter button (A)
repeatedly.
3.
Check
the
flame
indicator
(
B)
to
see
whether
the
flame
is
alight.
4. Keep the safety device control (C) depressed for a further 10-15 seconds.
5. Release the safety device control (C) and again check to see that the flame is alight.
If the burner has not lit after 4-5 attempts, turn off the gas tap, wait 5 minutes and then try to re-light. If the
burner still fails to light, please contact the authorised service provider in your area.
To terminate gas operation, turn off the gas valve from the gas container.
Regulating the temperature
The position number refers to fig. 1.
It will take several hours for the refrigerator to reach normal operating temperature.
The temperature of the main compartment of the refrigerator is controlled by a thermostat. The thermostat
knob (D) should be set at 1-4. If a lower (colder) temperature is desired, set the thermostat to a higher figure.
Please note that too much lower temperature might make vegetable or egg frozen..
Turning Off The Refrigerator
If the refrigerator is not to be used for some time:
1. Shut off any valve in the gas line to the refrigerator.
2. Empty the refrigerator. Defrost and clean it as described in the following paragraph. It must be completely
dry inside to avoid mold growth (if possible have the door open).
3. Set the thermostat button to the minimum position;
A: Piezo igniter
B: Flame indicator
C: Safety valve
D: Thermostat knob