P8701-M0 rev 08/07 Hand Pumps Instruction Manual MODELS: P8701 & P8701M SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-891-6599 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com ! This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
Save these instructions. For your safety, read and understand the information contained within. The owner and operator shall have an understanding of this product and safe operating procedures before attempting to use this product. Instructions and safety information shall be conveyed in operator’s native language before use of this product is authorized. Make certain that the operator thoroughly understands the inherent dangers associated with the use and misuse of the product.
! WARNING • Study, understand, and follow all instructions provided with and on this device before use. • All WARNING statements must be carefully observed to help prevent personal injury. • No alteration shall be made to this device. • Always wear protective gear when operating hydraulic equipment. • Keep hydraulic equipment away from flames and heat. Hydraulic fluid can ignite and burn. Do not operate if leaks are detected. • Crush Hazard. Keep hands and feet away from loading area.
OPERATION BEFORE USE ! ALWAYS monitor pressure, load or position using suitable equipment. Pressure may be monitored by means of an optional manifold and gauge (contact BVA Hydraulics). Load may be monitored by means of a load cell and digital indicator. Correct application position can only be determined by the operator of the equipment. 1.
(a) 4-way, 3-position valve for Double Acting Cylinder Port B 2 Port B Port A Port A Port A Port B 3 1 Port B P R Position 1: Pressured oil flows to port A, port B returns flow to reservoir P R Position 2: Neutral, ports A and B are closed. Hold Position. P R P R Position 3: Pressured oil flows to port B, port A returns flow to reservoir.
Hand Pumps Service Parts MODELS: P8701 & P8701M SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-891-6599 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com P8701-M0 08/07 Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence.
Hand Pumps Service Parts MODELS: P8701 & P8701M SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-891-6599 E-mail: sales@bvahydraulics.com Website: www.bvahydraulics.com Note: Not all components of the pump are replacement items, but are illustrated as a convenient reference of location and position in the assembly sequence. P8701-M0 08/07 Parts List Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Part No.
TROUBLESHOOTING GUIDE The following information is intended as an aid in determining if problem exists. Pumps should be repaired only by authorized BVA Service Center. For repair service, contact service center in your area. Symptom Erratic application action Application does not extend, move or respond to pressurized fluid Application responds to pressurized fluid, but system does not maintain pressure Application responds slower than normal Application does not return fluid to pump (i.e.