Note
If a value is not bypassed by pressing
C within 10 seconds,
the detector automatically proceeds to the next date/time
option. If the Time Minute value was not bypassed, the detec-
tor automatically proceeds to the Exit screen.
If a new value is selected but not confirmed by pressing
C
within 10 seconds, NO displays and the detector proceeds to
the next date/time option. If a new Time Minute value was
selected but not confirmed, the detector automatically pro-
ceeds to the Exit screen.
Passcode Protection Option
The passcode protection option (PASS) prevents unauthorized access
to the user options and the calibration/set alarm setpoint functions.
The passcode protection option can be enabled or disabled.
Note
The detector is shipped with the passcode protection option
disabled.
Enable Passcode Protection
To enable passcode protection, complete the following:
Note
The passcode is provided on a separate card inside the ship-
ping container.
1. From the EXIT screen of the user options menu, press
D or E
to scroll to the PASS option.
2. Press
C to select the option.
3. Set and PASS continually flash. Press
D or E to scroll to the
required passcode, and press
C to confirm the selection.
4. The ON screen displays and flashes continually. Press
C to
confirm. The LCD then returns to the EXIT screen.
5. Press
D or E to select another user option, or press C to exit
the user options and return to normal operation.
Note
If an incorrect passcode is selected or a correct passcode is
not confirmed within 10 seconds, NO displays and the LCD
returns to the EXIT screen.