Product manual

GasAlert Extreme
Quick Reference Guide
12
4. Insert the new battery.
5. Re-assemble the detector. When assembling the
detector be aware of the following:
Clean the seal on the front and rear shells with a
soft damp clean cloth. Do not use solvents,
soaps, or polishes. Refer to Internal Seals of the
GasAlert Extreme.
Ensure the front and rear shells are properly
aligned to ensure a proper environmental seal.
Torque the screws to 3-4 in-lbs in a crisscross
pattern to ensure a proper environmental seal.
Do not overtighten.
Replacing the Sensor
To replace a sensor, complete the following. Refer to Internal
Parts of the GasAlert Extreme and Internal Seals of the
GasAlert Extreme.
1. Deactivate the detector.
2. Remove the four machine screws on the rear shell
and remove the rear shell.
3. Remove the two machine screws from the PCB.
4. Remove the PCB. Place the PCB on a clean, non-
conductive surface.
5. Replace the sensor.
Note
Allow the new sensor 5 minutes to stabilize before
use. For a new ETO or NO sensor, allow the new
sensor 2 hours to stabilize before use.
6. Re-assemble the detector. When assembling the
detector, perform the following:
Clean the seal on the front and rear shells with a
soft damp clean cloth. Do not use solvents,
soaps, or polishes. Refer to Internal Seals of the
GasAlert Extreme.
Ensure the front and rear shells are properly
aligned to ensure a proper environmental seal.
Torque the screws to 3-4 in-lbs in a crisscross
pattern to ensure a proper environmental seal.
Do not overtighten.
Cleaning a Sensor Screen
Clean or replace the sensor screen as required. If replacement
sensor screens are required, refer to Replacement Parts and
Accessories in the GasAlert Extreme User Manual.
To clean a removed sensor screen, complete the following.
Refer to Internal Parts of the GasAlert Extreme
and Internal
Seals of the GasAlert Extreme.
1. Deactivate the detector.
2. Remove the four machine screws on the rear shell
and remove the rear shell.
3. Remove the two machine screws from the PCB.