User Manual

NÜO AWA Manual
Introduction
5
Features Wiring
The built-in piped cable used to connect the reader has the following technical characteristics:
- Gauge: 0.22 mm
- Arrangement: 2 twisted pairs
- Resistance: <2 Ohms
A minimum distance of 12 cm must be maintained for installations using doors with 2 input/output
readers or if there are 2 readers that are very close together.
TYPE OF WIRING AND WIRING DISTANCE:
WIRING SPECIFICATIONS:
DISTANCE BETWEEN READERS:
NÜO AWA
The NÜO AWA reader incorporates a male overhead connector.
NÜO AWA is supplied with a 3.5 metre piped cable with 4 wires (2 twisted pairs) and a female connector
at one end to correctly connect it.
The other end of the piped cable is connected to a single door controller or to the corresponding Wili
following the simple colour coding.
The wiring distance from the reader and the single door controller or Wili should not
exceed 25 metres in length under any circumstances.
Orange
O/W
Green
-
A
B
+
BY B US
G/W
3.5 metres of cable