User's Manual
Diagrams
59
NÜO DC Go! 8
NÜO Go! Manual
CONNECTIONS:
SDU+ - ENTRY READER
SDU+ - EXIT READER
SDU+ - LOCK
SDU+ - MAGNETIC SENS
SDU+ - PUSH BUTTON
SDU+ - INPUTS
SDU+ - OUTPUTS
BB 2
(2 x 2 x 0,22mm)
(
AWG24, twisted and shielded)
LOCK
RS-485 ELECTRONIC
LOCK
EXIT READER
MAGNETIC
SENSOR
24 VDC
OR
GR
GR
OR
W
W
SH
LOCK
24 V
Orange
O/W
Green
-
A
B
+
BB 2
G/W
8 W max
C
S
P
PUSH BUTTON
OR
GR
GR
OR
W
W
SH
ENTRY READER
Orange
O/W
Green
-
A
B
+
BB 2
G/W
2 DIGITAL INPUTS
2 DIGITAL OUTPUTS
To DC Go!8 Controller
BB4
BB2
2 1
2
1
NC
NO
C
NC
NO
C
OR
GR
GR
OR
W
W
SH
Relay outputs, 60W 2A 30VDC;
260mA 230VAC: 2.000V rms
6.1.7. DETAILED DIAGRAM SDU+ CONNECTION
At least one reader should be connected to the door or it must to be a Face Reader
connected or it should be set up as an emergency door.
The use of incorrect wiring can damage the equipment irreversibly.
The 24VDC "Lock" can be connected at the same time as the Auxiliary Bus, delivering it at
PRVW:EXWWKHVXPRIERWKPXVWEH DW: