User's Manual

Diagrams
61
NÜO DC Go! 8
NÜO Go! Manual
6.2.2. VOXTER AND READERS CONNECTION TO WILI+
The use of incorrect wiring can damage the equipment irreversibly.
LOCK OUTPUT:
Lock 24VDC, 8W Max
*It cannot be connected at the same time as the Auxiliary Bus or it cannot exceed
the sum of 10W between both of them)
MAGNETIC
SENSOR
LOCK
24 VDC
PUSH BUTTON
Entry Reader
Exit Reader
485 Lock
2 Digital Inputs
2 Digital Outputs
Voxter
WILI+
GR
W W W
INTERCOM
W
GR
OR
OR
BL
BL
BR
BR
SH
PoE+
Switch
Network
Relay Outputs, 60W 2A 30VDC;
260mA 230VAC: 2.000V rms
BB2
BB2 (485)
2 x 2 x (stranded 7x0.19mm
copper + 1.3HDPE) + drain wire
(stranded 7x0.19mm)
AWG24, twisted and shielded
BB4
BB4 (Ethernet and RS-485)
4 x 2 x (stranded 7x0.19mm copper +
0.9HDPE) + drain wire (stranded
7x0.19mm)
AWG24, twisted and shielded