User manual

C-COM Satellite Systems Inc.    Page 84 of 128 
iNetVu™ 7000 Controller User Manual 
Revision 1.19
7000 Controller Power Output Range Option Capabilities: 13, 14, 18, 19, 20, 21 V @ 
500mA (max) 
If the user chooses to power the LNB from the controller, he/she should verify the 
power/voltage range requirements of the LNB in use, and configure the iNetVu
TM
 7000 
Controller according to those power/voltage requirements. 
TR No. (Transponder Number) 
There are Six (6) Transponder values in the 7000 Controller for each satellite. 
Transponder 0-2 (TR0_H – TR0_H) are horizontal receive 
Transponder 3-5 (TR3_V –TR5_V) are vertical receive. 
The user may override the default values saved in the controller with his/her transponder 
information (frequency, symbol rate, FEC rate) 
Frequency (KHz), Code Rate, Symbol Rate (Ksps) 
The frequencies listed have been converted to L-band from Ku-band, and the ranges are 
950000-2150000 KHZ, based on a LO frequency of 10750 MHZ. 
The user may select from the six (6) available transponders saved in the 7000 
Controller, which are specific to each satellite, or he/she may also enter valid 
transponder data manually. 
DVB will base satellite acquisition on three satellite transponder parameters, them being: 
Frequency 1 (KHz) 
L-Band Receive Frequency 
Symbol Rate 1 (Ksps) 
Symbol Rate of receive signal 
Code Rate 
FEC Rate of receive signal 