7.2.2.9. Azimuth Parameters 
The Azimuth menu allows for the configuration of the azimuth axis. Options include the 
setting of the pot zero, and the pot factor, as well as the axis limit functionality, the slow 
speed setting, and current limits for fast and slow speeds. 
Fig. 75: 
Maintenance - Azimuth Parameters 
Slow Speed 
The iNetVu
TM
 software basis the default azimuth motor slow speed on the platform size 
and type. See appendix 3, table 5 for details. The user may change this value, however 
changing such value could result in difficulty with satellite acquisition. 
Limit Switches (ST_DIS, LR_DIS) 
Allows for enabling and disabling the ST (STOW) and LR (Azimuth Left and Right) limits. 
A check mark in the box implies the limit has been DISABLED. By default the boxes are 
left unchecked. Please be advised that disabling any of these limits should be done 
under the direct supervision of a C-Com Satellite Systems Inc. technical support 
representative.
Note: The LR limit is for future development purposes, and is not functional at the time 
of publication. 
Current Settings 
H_P_C (9) and L_P_C (6) represent high platform current (Amps) @ speed 9, and low 
platform current @ speed 6 respectively. A software controlled current protection for the 
Mobile Platform’s elevation motors. For Motor Speeds that are not listed (Speed 1, 2, 4, 
5, 7, 8), the Current Limit for those speeds is calculated using a percentage of the 
Current Limit @ speed 6 and 9. See appendix 3, table 5 for the default current limits for 
all iNetVu
TM
 Mobile Platforms. 
• Current Limit 8 – 90% of Current Limit 9 
• Current Limit 7 – 80% of Current Limit 9 
• Current Limit 5 – 90% of Current Limit 6 
• Current Limit 4 – 80% of Current Limit 6 