1. Conguration of the Switching Inputs (IN1, IN2, IN3, IN4, IN5)
Theswitchinginputsarepresenttodeterminemisconduct.Inthesimplestcase,e.g.activation(Low->High=LH),
deactivation(High->Low=HL)ortoggling(Low->High->Low=LHL)mayberecognisedandanalarmbegener-
ated.Alarmingviatheswitchinginputisdeactivatedbydefault.Thefollowingcommandisneededforactivating:
SET <IN1/IN2/…/INn> <OFF/LH/HL/LHL> [<Time>] #1513
TIME:1to255seconds,optionalparameter(thetimehasatoleranceof+/-1s)
Theoptionalparameter<TIME>cansetthatanalarmisnottriggeredatonceaftertheankbutonlyafterasettime.
Thismaybebalanceout,e.g.interferences.
Afterthiscommand,anoverviewofthecurrentcongurationisreturnedbytextmessage.
GX155
TEMP:18.0C
Min.Temp.OFF
Max.Temp.OFF
HYSTEMP:0.2C
IN1:OFF
IN2:LH
IN3:LH
IN4:LH
IN5:LH
Thesametextmessageissentwiththesamecommand:
TEST <IN1/IN2/…/INn> #1513
AllINx-functionsareresettofactorysettingswiththecommand:
RESET <IN1/IN2/…/INn> #1513
With the function ALARM (not ALARM ENABLE) you can instruct the relays to perform an action in case of
alarm.