FORWARD CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS 130MT.K 160MT.K UNITS
Maximum DC output current
at case temperature
I
O
120° rect. conduction angle
130 (160) 160 (200) A
85 (62) 85 (60) °C
Maximum peak, one-cycle
forward, non-repetitive surge
current
I
TSM
t = 10 ms
No voltage
reapplied
Initial
T
J
= T
J
maximum
1130 1430
A
t = 8.3 ms 1180 1500
t = 10 ms
100 % V
RRM
reapplied
950 1200
t = 8.3 ms 1000 1260
Maximum I
2
t for fusing I
2
t
t = 10 ms
No voltage
reapplied
64 000 102 000
A
2
s
t = 8.3 ms 5800 9300
t = 10 ms
100 % V
RRM
reapplied
4500 7200
t = 8.3 ms 4100 6600
Maximum I
2
√t for fusing I
2
√t t = 0.1 to 10 ms, no voltage reapplied 64 000 102 000 A
2
√s
Low level value of
threshold voltage
V
T(TO)1
(16.7 % x π x I
T(AV)
< I < π x I
T(AV)
),
T
J
maximum
0.78 0.81
V
High level value of
threshold voltage
V
T(TO)2
(I > π x I
T(AV)
), T
J
maximum 0.99 1.04
Low level value of forward slope
resistance
r
f1
16.7 % x π x I
T(AV)
< I < π x I
T(AV)
),
T
J
maximum
4.59 3.52
mΩ
High level of forward slope
resistance
r
f2
(I > π x I
T(AV)
), T
J
maximum 4.17 3.13
Maximum forward
voltage drop
V
FM
I
pk
= 200 A, T
J
= 25 °C,
t
p
= 400 µs single junction
1.63 1.49
V
RMS isolation voltage V
ISOL
T
J
= 25 °C, all terminal shorted
f = 50 Hz, t = 1 s
4000
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS 130MT.K 160MT.K UNITS
Maximum junction operating
and storage temperature range
T
J
, T
Stg
- 40 to 150 °C
Maximum thermal resistance,
junction to case
R
thJC
DC operation per module 0.16 0.12
K/W
DC operation per junction 0.93 0.73
120° rect. condunction angle per module 0.18 0.15
120° rect. condunction angle per junction 1.08 0.88
Maximum thermal resistance,
case to heatsink
R
thCS
Per module
Mounting surface smooth, flat and greased
0.03
Mounting
torque ± 10 %
to heatsink
A mounting compound is recommended
and the torque should be rechecked after
a period of 3 hours to allow for the
spread of the compound.
Lubricated threads.
4 to 6
Nm
to terminal 3 to 4