6121 Baker Road, Suite 108 Minnetonka, MN 55345 Phone (952) 933-6190 Fax (952) 933-6223 1-800-274-4284 www.chtechnology.com Thank you for downloading this document from C&H Technology, Inc. Please contact the C&H Technology team for the following questions - Technical Application Assembly Availability Pricing Phone – 1-800-274-4284 E-Mail – sales@chtechnology.com www.chtechnology.com - SPECIALISTS IN POWER ELECTRONIC COMPONENTS AND ASSEMBLIES - www.chtechnology.
CM400DU-34KA Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Dual IGBTMOD™ KA-Series Module 400 Amperes/1700 Volts A B F TC MEASURED POINT G CL M T - (4 TYP.) N G2 Z E2 P E2 C2E1 C1 C E CL X Q G1 E1 AA LABEL R Y P Description: Powerex IGBTMOD™ Modules are designed for use in switching applications.
Powerex, Inc.
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM400DU-34KA Dual IGBTMOD™ KA-Series Module 400 Amperes/1700 Volts Thermal and Mechanical Characteristics, Tj = 25 °C unless otherwise specified Characteristics Symbol Test Conditions Typ. – – Max. Units Rth(j-c)Q Thermal Resistance, Junction to Case Rth(j-c)D Per FWDi 1/2 Module – – 0.11 °C/W Rth(c-f) Per Module, Thermal Grease Applied – 0.010 – °C/W Tc Measured Point – – 0.
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM400DU-34KA Dual IGBTMOD™ KA-Series Module 400 Amperes/1700 Volts REVERSE RECOVERY CHARACTERISTICS (TYPICAL) REVERSE RECOVERY TIME, trr, (ns) SWITCHING TIME, (ns) tf td(off) td(on) 103 102 VCC = 1000V VGE = ±15V RG = 1.0Ω Tj = 125°C INDUCTIVE LOAD 101 100 tr 101 102 VCC = 1000V VGE = ±15V RG = 1.0Ω Tj = 25°C INDUCTIVE LOAD trr 102 100 10-2 10-1 101 Single Pulse TC = 25°C Per Unit Base = Rth(j-c) = 0.