12-3 Reverse recovery current characteristics
0
100
200
300
400
500
0 100 200 300 400 500 600 700
Reverse recovery current Irr [
A
]
Ls = 100nH,
Inductive load
Tj = 125°C, V
R
= 2250V
Forward current I
F
[A]
Reverse recovery current characteristics (typical)