Installation manual

SYSTEM 238 Installation Manual
6
Option Location
Combination Command 09 (2)
Daily Battery Test Enable 2F (2)
Delay Before Dial by Loop 30 - 37 (4)
Delay Before Dial Time 0B (1)
Dial Attempts 0B (6)
Dial Type 0B (2)
Disable Loop LEDs 2E (5)
Door Chime Enable by Loop 30 - 37 (1)
Duress Report Code 2D (1)
Duress Report Receiver 2D (2)
Emergency Bell Type 27 (4)
Emergency Report Code 27 (1 - 2)
Emergency Receiver Select 27 (3)
Entry Delay Time 2D (3)
Entry Pre-alarm Enable 2E (1)
Exit Delay Time 2D (4)
Exit Pre-alarm Enable 2E (2)
Faulted Arming Type 09 (4)
Fire Bell Type 28 (4)
Fire Report Code 28 (1 - 2)
Fire Receiver Select 28 (3)
Four Minute Power Up Delay Enable 2F (3)
Group Shunt Enable 30 - 37 (3)
Guest Combination 08 (2 - 6)
Guest Combination Time 09 (1)
Installer Combination 00 (1 - 6)
Keypad RPS Enable 0B (3)
Local System Only 2F (1)
Loop Arming Type 1F - 26 (4)
Loop Audible Type 1F - 26 (5)
Loop Circuit Type 1F - 26 (6)
Loop Receiver Select 1F - 26 (1)
Loop Response Time 1F - 26 (2)
Loop Restore Type 1F - 26 (3)
Master Code (User #1) 01 (2 - 6)
Opening Report Code 2C (1)
Opening Report Receiver 2C (2)
Police Bell Type 29 (4)
Police Report Code 29 (1 - 2)
Police Receiver Select 29 (3)
Phone Ring Type 0B (5)
Receiver #1 Message Format 0A (2)
Receiver #1 Phone Number 0D - 0F (1 - 6)
Receiver #1 Receive Format 0A (1)
Receiver #2 Message Format 0A (4)
Receiver #2 Phone Number 11 - 13 (1 - 6)
Receiver #2 Receive Format 0A (2)
Restoral Reporting Code by Loop 17 - 1E (3 - 4)
Restore Receiver Select 2A (2)
Ring Back Enable 2E (4)
RPS Enable 0B (4)
RPS Phone Number 14 - 16 (1 - 6)
Set Test Report Countdown Timer A0 (1)
Shunt Enable 30 - 37 (2)
Shunt Receiver Select 2A (1)
Shunt Reporting Code 17 - 1E (5 - 6)
Soft Zone Operation Enable 2F (4)
Test Report Code 2B (1 - 2)
Test Report Interval 2B (4)
Test Report Receiver Select 2B (3)
Unit Status Code 2A (3)
Unit Status Receiver 2A (4)
User Arming Type 01 - 08 (1)
User Combinations 01 - 08 (2 - 6)
You can program the SYSTEM 238 from the LED or Alpha keypad,
or remotely using the COMMANDER II software. Remote program-
ming information can be found in the COMMANDER II/MONITOR II
Operating Manual. This manual contains a brief description of each
programming option beginning on page 8.
PROGRAMMING THE PANEL
All panel wiring for the SYSTEM 238 should be completed prior to
applying power. You can only access the programming mode
when the control panel is disarmed.
NOTE: Command Location A0 must be addressed directly. When
programming this Command Location with an Alpha keypad, the
previously stored data is not displayed. To program this location,
enter the Command Location followed by the [#] key. Then enter the
data to be stored and again press the [#] key.
Warning: If you enter a Command Location and then press the [#]
key without entering any program data, the keypad will beep 5 times,
indicating an error. To correct this problem, simply re-enter the
Command Location and Data, then press the [#] key.
Programming with the LED Keypad
Programming with an LED keypad is a one-step process. Key in the
two-digit address (Command Location), followed immediately by the
desired programming values (program data), then press the [#] key
to store the data. The LED keypad does not display any pro-
grammed values. If you are not sure that the correct programming
values have been entered, program the Command Location again.
To Start Keypad Programming
Key in the [Installer Combination] [*] [0] [#]. The default Installer
Combination is 0 1 2 3 4 5. The programming mode is indicated
by the Program LED being lit on the LED keypad or CMD DATA
being displayed across the top row of the LCD display for the
Alpha keypad.
Programming with the Alpha Keypad
Entering program data with an Alpha keypad is a two-step process.
First, key in the two-digit address (Command Location) to be
programmed and press the [#] key. The Alpha keypad displays the
Command Location and the data previously stored. Enter the new
data you wish to store and press the [#] key to write the data. You
can also scroll through the Command Locations in numerical order
by alternately pressing and releasing the [#] key.
NOTE: To program Command Location A0 with an LED keypad,
remember to enter the Command Location, followed by the program
data, then press the [#] key.
Data is programmed into the panel using the hexadecimal number
system, which consists of the digits 0 - 9 and the letters A - F. The
digits 0 - 9 are entered directly from the keypad. The chart below
shows how to enter the hexadecimal digits A through F.
Programming Hexadecimal Numbers
The Alpha keypad may be used to program the control panel. The
cursor is moved using the "E" and "P" keys, as indicated in the
figure below. The "F" key enters a blank space and moves the
cursor one position to the right.