Specifications
Appendix E Display Cluster Protocol 263
load Load a complete show specification from a local file associated with the show 
name specified by the first parameter. Busy feedback may be sent to the host 
while loading, informing the host about the progress (see “Busy” on page 
270). If errors occur, Error feedback is sent (see “Error” on page 271). Finally, 
a Ready feedback message is sent, regardless of whether any error occurred 
(see “Ready” on page 269).
load "Phantom"
◆ NOTE: You can not specify a folder path to the show. The show must be 
present in the “Shows” folder, located in the same folder as the 
WATCHOUT display software.
Parameter Description
<string> Name of the show to be loaded.
[<bool>] Manage cluster loading and feedback. Defaults to true.
[<bool>] Designate as the master display computer. Defaults to true.
[<uint>] Conditional layer enable flags, least significant bit is condition 1 (see table 
on page 255).