Instruction manual

C.Scope Locator: Function Checks
It is recommended that the operation of the Locator and Generator/
Transmitter is regularly checked using the C.Scope Function Checker.
If a Function Checker is not available then follow the procedure below:
Locator:
Battery Condition
Check by depressing the On/Off Switch beneath the handle.
The display will show at least two solid segments if the batteries are OK.
Ensure power on tone is heard.
Power Mode
Select Power Mode. Set sensitivity fully clockwise and point the body of the
Locator at a fluorescent light from a distance of one metre. Switch the light on.
A loud tone should be heard and the display should read greater than 50% full
scale. Reducing the sensitivity should cause the displayed reading to reduce
and the tone to cut out.
Radio Mode
Select Radio Mode. Set the sensitivity fully clockwise and, from a distance of
less than 0.25 metres, point the unit at a metal conductor of length greater
than 100 metres (for example a metal pipe or cable).
A warbling tone should be heard. The display should read greater than 50%
full scale.
All
Scan Mode
Select
All
Scan Mode. Repeat the same tests that were used to function check
the Power and Radio Modes.
48