TOOL CARE: We advise periodic use of “3 in 1” oil
on the plunger and other moving parts.
To Recalibrate MCT-101 Tools to Factory Settings
1. Remove wrench from storage compartment,
labeled Tool Box.
2. Loosen lock nut on plunger.
3. Open lever by depressing trigger.
4. Rotate wheel to full stop in blue position.
5. Use wrench as a gauge by positioning it horizon-
tally between support dogs and plunger tip. Place
legs of wrench against support dogs and flat end
of gauge across plunger tip.
6. Close lever while rotating plunger until it touches
flat end of gauge. Rotate plunger clockwise to
reduce gap and counterclockwise to increase gap.
Set plunger depth to hold gauge firmly when lever
is in closed position.
7. Release gauge by depressing trigger.
8. Rotate plunger another 1/4 turn until slot in
plunger tip is at top of tool.
9. Tighten lock nut with wrench to secure plunger
and return wrench to Tool Box compartment.
The MCT-101 tool is now calibrated for connectors on
all RG-6, -59 and –11 cables (except PCT TRS and PPC
EX connectors, which require a .710 dimension).