- CABLETRON Systems, Inc, SmartSwitch User's Guide 2E42-27, 2E42-27R, 2E43-27, 2E43-27R

Chapter 5: Local Management
5-70 2E42-27/2E42-27R/2E43-27/2E43-27R User’s Guide
OutNonUnicast (Read-Only)
This field displays the total number of frames transmitted to a broadcast
or multicast address.
OutDiscards (Read-Only)
The OutDiscards field displays the total number of outbound frames that
were discarded, even though the frames contained no errors. This field
may increment, because the switch needed to free up buffer space, or the
switch was being overutilized.
OutErrors (Read-Only)
This field displays the total number of outbound frames discarded
because they contained errors. This field represents the total number of
errored frames, regardless of the cause of the error.
OutQLen (Read-Only)
The OutQLen field displays the length of the frame queue. The field
represents the total number of frames contained in queue.
Address (Read-Only)
This field displays the MAC address of the interface that is currently
being displayed.
Last Change (Read-Only)
This field displays the last time that the interface was reset.
Admin Status (Read-Only)
This field displays the current status of the interface. If this field displays
“Testing”, no frames may be passed on this interface.
Oper Status (Read-Only)
This field displays the current status of the interface. If this field displays
“Testing”, no frames may be passed on this interface.
MTU (Read-Only)
The MTU field displays the maximum frame size (in octets) that a frame
may contain to be received or transmitted from this interface.