Owner manual

Chapter 3: Installation
3-8 2M46-04R/2M46-04RDC User’s Guide
3.4 CONNECTING POWER
The 2M46-04R connects to an ac power source and the 2M46-04RDC
connects to a dc power source. If you are connecting power to a
2M46-04R, proceed to section 3.4.1. If you are connecting power to a
2M46-04RDC, proceed to section 3.4.2.
3.4.1 Connecting Power to the 2M46-04R
To connect the 2M46-04R to the power sources, proceed as follows:
1. Insert the connector of each power cord into the two power supplies
and insert the plug of each power cord into a grounded wall outlet (see
Figure 3-7). To take advantage of the load sharing and redundancy
capabilities, each power cord must be plugged into a dedicated ac
outlet. The POWER LED turns ON (green) and the CPU LED turns
ON (green) briefly.
Figure 3-7 2M46-04R Rear View
NOTE
The 2M46-04R has two power supplies with automatic voltage
sensing that allow connection to power sources ranging from
100–125 Vac or 200–250 Vac, 50/60 Hz.
NOTE
It takes approximately one minute for the 2M46-04R to boot up.
Power Supplies
2363-62