SmartSwitch Series 2E42, 2E43, 2E48, 2E49, 2H22, 2H23, 2H28, 2H33 and 2M46 Local Management Supplement 9032971-01
NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
Notice CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems, Inc.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice CABLETRON SYSTEMS SALES AND SERVICE, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Cabletron Systems Sales and Service, Inc.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice CABLETRON SYSTEMS LIMITED PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE UNITED STATES OF AMERICA AND BY UNITED STATES OF AMERICA GOVERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT.
Notice If the Program is exported from the United States pursuant to the License Exception TSR under the U.S.
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Name: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: 89/336/EEC 73/23/EEC Cabletron Systems, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03867 Mr. J.
CONTENTS Figures ................................................................................................... xiii Tables..................................................................................................... xiv CHAPTER 1 CHANGES TO LOCAL MANAGEMENT SCREENS 1.1 Introduction.................................................................................. 1-1 1.2 Accessing Local Management..................................................... 1-2 1.2.
Contents 1.17 Summary of VLAN Local Management......................................1-43 1.18 802.1Q VLAN Configuration Menu Screen ................................1-44 1.19 IGMP/VLAN Configuration Screen.............................................1-45 1.19.1 Configuring VLANs for IGMP ........................................1-49 1.20 Priority/Multicast Configuration Menu Screen ............................1-50 1.21 Port Priority Configuration Screen .............................................1-52 1.21.
Contents CHAPTER 4 4.1 4.2 4.3 4.4 GENERIC ATTRIBUTE REGISTRATION PROTOCOL (GARP) GARP Switch Operation .............................................................. 4-1 4.1.1 GARP VLAN Registration Protocol (GVRP) ................... 4-1 GARP Multicast Registration Protocol (GMRP)........................... 4-3 GARP Operation Status Screen .................................................. 4-4 4.3.1 Setting a Port to Operate in GMRP or GVRP ................. 4-6 4.3.2 Setting All Ports on the Switch....
FIGURES Figure 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 1-12 1-13 1-14 1-15 1-16 1-17 1-18 1-19 1-20 1-21 1-22 2-1 2-2 2-3 3-1 3-2 3-3 3-4 4-1 4-2 4-3 5-1 Page 802.1D Switching Mode, LM Screen Hierarchy........................ 1-3 802.1Q Switching Mode, LM Screen Hierarchy ....................... 1-4 Example of a Local Management Screen ................................ 1-5 Device Configuration Menu Screen.......................................... 1-6 System Resources Information Screen................
TABLES Table Page 1-1 1-2 1-3 2-1 3-1 3-2 3-3 3-4 3-5 User’s Guides Affected by Revisions........................................1-1 TX Queue Mapping Default Values ........................................1-55 TX Priority Regeneration Default Values ................................1-56 ENET/Repeater Port Relationship ............................................2-6 CONN/Repeater Port Relationship ...........................................3-3 CONN/Network Organization......................................
CHAPTER 1 CHANGES TO LOCAL MANAGEMENT SCREENS This chapter introduces the scope of this document, new hierarchy, and new screens (except security screens) affected by the 4.08.xx and 4.09.xx firmware revisions. Chapter 2 describes the revised security screens for the 2E43-51 and 2E43-51R repeater devices. Chapter 3 describes the security screens for the 2H23-50R and 2H33-37R repeater devices. Chapter 5 describes a new Network Tools command, cdp. 1.
Chapter 1: Changes to Local Management Screens 1.2 ACCESSING LOCAL MANAGEMENT Access to Local Management is controlled through the Password screen. 1.2.1 Navigating Local Management Screens The Local Management application consists of a series of menu screens. Navigate through Local Management by selecting items from the menu screens. The SmartSwitch supports two modes of switch operation. The switching modes are as follows: • 802.1D Switching (traditional switching) • 802.1Q Switching (802.
Accessing Local Management \ Device Configuration Menu General Configuration SNMP Community Names Configuration SNMP Traps Configuration System Resources Information Flash Download Configuration Password High Speed Interface Configuration Port Configuration Menu 802.
Chapter 1: Changes to Local Management Screens Device Configuration Menu General Configuration SNMP Community Names Configuration SNMP Traps Configuration Ethernet Full Duplex Configuration System Resources Information Flash Download Configuration Password High Speed Interface Configuration Port Configuration Menu 802.1 Configuration Menu Device Menu Fast Ethernet Interfaces HSIM * SmartTrunk Configuration Switch Configuration Port Redirect Configuration/ Redirect Configuration Menu 802.
Accessing Local Management 1.2.2 Screen Format Since the top part of the screen contains the same type of information (the name of the screen, the SmartSwitch model number, the firmware revision, and the BOOT PROM revision), it is not shown in the following descriptions of the screens. Only the lower portion of the screens is shown in the following screen descriptions. The name of the screen is shown in the figure title for each screen. Figure 1-3 shows an example of the fields in a screen.
Chapter 1: Changes to Local Management Screens 1.3 DEVICE CONFIGURATION MENU SCREEN The Device Configuration Menu screen, Figure 1-4, provides access to Local Management screens that allow you to configure and monitor operating parameters, modify SNMP community names, set SNMP traps, configure switch parameters and configure ports. To access the Device Configuration Menu screen from the Device Menu screen, use the arrow keys to highlight the DEVICE CONFIGURATION menu item and press ENTER.
Device Configuration Menu Screen SNMP TRAPS CONFIGURATION Provides display and configuration access to the table of IP addresses used for trap destinations and associated community names. For details, refer to your SmartSwitch device user’s guide.
Chapter 1: Changes to Local Management Screens 1.4 SYSTEM RESOURCES INFORMATION SCREEN The System Resources Information screen, Figure 1-5, provides information concerning the processor used in the SmartSwitch and the amount of FLASH memory, DRAM, and NVRAM that is installed and how much of that memory is available. This screen is used to monitor the current switch utilization and the peak switch utilization.
System Resources Information Screen DRAM Installed (Read-Only) Indicates the amount of DRAM installed in the SmartSwitch and how much of it is currently available. NVRAM Installed (Read-Only) Indicates the amount of NVRAM installed in the SmartSwitch and how much of it is currently available. Current Switch Utilization (Read-Only) Shows the percentage of the device switching capacity currently being used.
Chapter 1: Changes to Local Management Screens 1.5 FLASH DOWNLOAD CONFIGURATION SCREEN The Flash Download Configuration screen, shown in Figure 1-6, is used to download a new image file from a TFTP server to Flash memory. NOTE The user may also force the download of an image by changing the position of dipswitch 6 located inside the device. Refer to your user’s guide for details. Before downloading an image to the device, copy the image to the network TFTP server.
FLASH Download Configuration Screen The following briefly defines each field of the Flash Download Configuration screen: Download Method (Selectable) This field steps between TFTP, RUNTIME and BOOTP. If set for BOOTP, the device sends out a BootP request to determine the IP address of the TFTP server and the filename of the image to be downloaded.
Chapter 1: Changes to Local Management Screens Download Server IP (Selectable) The IP address of the TFTP server to be used for the FLASH download is entered in this field. Download File Name (Selectable) The complete TFTP server path and file name of the new image is entered in this field. 1.5.1 Image File Download Using TFTP Set the SmartSwitch device to download to FLASH using TFTP as follows: 1. Use the arrow keys to highlight the Download Method field. 2. Use the SPACE bar to select TFTP. 3.
FLASH Download Configuration Screen 1.5.2 Image File Download Using Runtime Set the SmartSwitch device to download to FLASH using RUNTIME as follows: 1. Use the arrow keys to highlight the Download Method field. 2. Use the SPACE bar to step to RUNTIME. 3. Use the arrow keys to highlight the Reboot After Download field. 4. Use the SPACE bar to select either YES or NO. Select YES if you want the device to reboot after the download is complete.
Chapter 1: Changes to Local Management Screens 1.5.3 Image File Download Using BootP Set the SmartSwitch device to download to FLASH using BootP as follows: 1. Use the arrow keys to highlight the Download Method field. 2. Use the SPACE bar to select BOOTP. 3. Use the arrow keys to highlight the TFTP Gateway IP Addr field. 4. Set the IP address of the TFTP gateway server (this defaults to the same IP address set in the TFTP Gateway IP Addr field in the General Configuration screen). 5.
Port Configuration Menu Screen ETHERNET FULL DUPLEX CONFIGURATION HIGH SPEED INTERFACE CONFIGURATION SMARTTRUNK CONFIGURATION PORT REDIRECT CONFIGURATION BROADCAST SUPPRESSION CONFIGURATION REPEATER CONFIGURATION MENU EXIT RETURN 27622-20 Figure 1-7 Port Configuration Menu Screen The following briefly defines each selectable item of the Port Configuration Menu screen: ETHERNET FULL DUPLEX CONFIGURATION The Ethernet Full Duplex Configuration screen allows each 10 Mbps port to be set for either Standar
Chapter 1: Changes to Local Management Screens PORT REDIRECT CONFIGURATION Used to access the Redirect Configuration Menu screen, which provides access to the Port Redirect Configuration and VLAN Redirect Configuration screens. For details, refer to Section 1.10. BROADCAST SUPPRESSION CONFIGURATION Used to set a desired limit of received broadcast frames that are forwarded out other interfaces. For details, refer to Section 1.13.
Ethernet Full Duplex Configuration Screen PORT # OPERATION MODE LINK STATUS PORT STATUS 1 [STANDARD ENET] Link ENABLED 2 [STANDARD ENET] Link ENABLED 3 [STANDARD ENET] Link ENABLED 4 [STANDARD ENET] No Link ENABLED 5 [STANDARD ENET] Link ENABLED 6 [STANDARD ENET] Link ENABLED 7 [STANDARD ENET] Link ENABLED 8 [STANDARD ENET] Link ENABLED 9 [STANDARD ENET] Link ENABLED 10 [STANDARD ENET] Link ENABLED 11 [STANDARD ENET] Link ENABLED 12 [STANDARD ENET] Link EN
Chapter 1: Changes to Local Management Screens LINK STATUS (Read-only) Indicates whether there is a physical connection from this port to another Ethernet device. One of the following values displays: • Link – A link signal is present; there is a valid physical connection from this port to another device. • No Link – No link signal is present; there is no valid physical connection from this port to another device.
High Speed Interface Configuration Menu Screen To set the Operational Mode for individual ports, proceed as follows: 1. Use the arrow keys to highlight the Operation Mode field adjacent to the number of the port(s) that you plan to change. NOTE The Operation Mode for the first 12 ports can be changed on the first screen. To display the Operation Mode for additional groups of twelve ports (13 – 24, 25 – 36, and 37 – 48), use the arrow keys to highlight the Ports [xx-xx] field and press ENTER. 2.
Chapter 1: Changes to Local Management Screens To access the High Speed Interface Configuration Menu screen from the Port Configuration Menu screen, use the arrow keys to highlight the HIGH SPEED INTERFACE CONFIGURATION menu item and press ENTER. The High Speed Interface Configuration Menu screen, Figure 1-9, displays.
High Speed Interface Configuration Screen 1.9 HIGH SPEED INTERFACE CONFIGURATION SCREEN The High Speed Interface Configuration screen, Figure 1-10, applies only to installed optional Fast Ethernet Interface Modules. This screen supports the FE-100TX, FE-100FX, FE-100F3, and FE-100LH Fast Ethernet Interface Modules that operate at 100 Mbps.
Chapter 1: Changes to Local Management Screens The following briefly explains each field of the High Speed Interface Configuration screen. Port Type (Read-only) Displays the type of interface (FE-100FX, FE-100TX, FE-100F3, FE-100LH, or Unknown) installed. Figure 1-10 shows that there is an FE-100TX interface installed in one optional port slot and no interface indicated by Unknown in another optional port slot.
High Speed Interface Configuration Screen NOTE In normal operation, the port with an FE-100TX installed automatically establishes a link with the device at the other end of the segment without requiring user setup. However, Local Management provides the user with the option of manually configuring that port. If an FE-100TX is installed, the field steps to Auto-Negotiation, 10Base-T, 10Base-TFD (full duplex), 100Base-TX, and 100Base-TXFD (full duplex).
Chapter 1: Changes to Local Management Screens 1.9.2 Setting the FE-100FX or FE-100F3 Operational Mode Use this field to set the active technology. This field toggles between 100Base-FX and 100Base-FXFD (full duplex). To set the active technology through Local Management, proceed as follows: 1. Use the arrow keys to highlight the Desired Operational Mode field. 2. Use the SPACE bar to select 100Base-FX or 100Base-FXFD (full duplex). 3. Press ENTER. The port now operates in the chosen mode. 4.
High Speed Interface Configuration Screen 3. Use the arrow keys to highlight the SAVE command. Press ENTER. The message “SAVED OK” displays and Local Management saves the changes to memory. The selected mode is displayed in both the Desired Operational Mode field and the Current Operational Mode field. 1.9.5 Setting the FE-100TX Advertised Ability In normal operation, an FE-100TX auto-negotiates to the highest speed possible.
Chapter 1: Changes to Local Management Screens 1.10 REDIRECT CONFIGURATION MENU SCREEN The Redirect Configuration Menu screen (Figure 1-11) provides access to the Port Redirect Configuration and VLAN Redirect Configuration screens. Any combination, up to 128, of port and/or VLAN redirect instances can be configured. To access the Redirect Configuration Menu screen from the Port Configuration Menu screen, use the arrow keys to highlight the PORT REDIRECT CONFIGURATION menu item and press ENTER.
Port Redirect Configuration Screen 1.11 PORT REDIRECT CONFIGURATION SCREEN The Port Redirect Configuration screen, Figure 1-12, enables the user to redirect frames from one source port to one destination port. Frames received on the source port can be redirected and transmitted in the frame format in which they are received (normal), or they can be redirected with a VLAN Tag (TAGGED) or without a VLAN Tag (UNTAGGED).
Chapter 1: Changes to Local Management Screens To access the Port Redirect Configuration screen from the Redirect Configuration Menu screen, use the arrow keys to highlight the PORT REDIRECT CONFIGURATION menu item and press ENTER. The Port Redirect Configuration screen displays.
Port Redirect Configuration Screen Frame Format (Read-Only) Displays the current frame format setting: NORMAL, TAGGED or UNTAGGED The default is NORMAL. • NORMAL – Frames are redirected in the format that they were received or transmitted on the source port. • TAGGED – Frames are transmitted on the destination port with a VLAN tag inserted according to the frame classification.
Chapter 1: Changes to Local Management Screens 1.11.1 Changing Source and Destination Ports To add or delete source port and destination port entries and set the Frame Format and Redirect Errors functions, proceed as follows: 1. Use the arrow keys to highlight the Source Port field near the bottom of the screen. 2. Press the SPACE bar or BACKSPACE one or more times to increment or decrement the port number displayed in the brackets [n] until the appropriate port number displays. 3.
VLAN Redirect Configuration Screen TIP If more than one port is being redirected, repeat steps 1 through 10 for each additional setting. Then go to step 11 to save all the new settings at once. If an entry is to be changed, delete the entry, save the screen, then recreate the entry with its new settings.
Chapter 1: Changes to Local Management Screens To access the VLAN Redirect Configuration screen from the Redirect Configuration Menu screen, use the arrow keys to highlight the VLAN REDIRECT CONFIGURATION menu item and press ENTER. The VLAN Redirect Configuration screen displays.
VLAN Redirect Configuration Screen Frame Format (Read-Only) Displays the current frame format setting: RECEIVED, TAGGED or UNTAGGED. The default is RECEIVED. • RECEIVED – Frames are redirected in the format that they were received by the SmartSwitch device. • TAGGED – Frames are transmitted on the destination port with a VLAN tag inserted according to the frame classification of the receiving port.
Chapter 1: Changes to Local Management Screens 1.12.1 Changing Source VLAN and Destination Ports To add or delete source VLAN and destination port entries and set the Frame Format, proceed as follows: 1. Use the arrow keys to highlight the Source VLAN field near the bottom of the screen. 2. Type in the VLAN ID number of the source VLAN to be configured. 3. Use the arrow keys to highlight the Destination Port field near the bottom of the screen. 4.
Broadcast Suppression Configuration Screen 9. Use the arrow keys to highlight SAVE at the bottom of the screen. Press ENTER. The message “SAVED OK” displays. This saves the new settings and updates the Source Port and Destination Port read-only fields. 1.13 BROADCAST SUPPRESSION CONFIGURATION SCREEN The Broadcast Suppression Configuration screen, Figure 1-14, enables the user to set a desired limit of receive broadcast frames that are switched out to the other ports.
Chapter 1: Changes to Local Management Screens The following explains each field of the Broadcast Suppression screen: PORT # (Read-Only) Identifies the number of the port. Total RX (Read-Only) Displays the total number of broadcast frames received. Peak Rate (Read-Only) Displays the highest number of broadcast frames received in a one-second interval. Time Since Peak (Read-Only) Displays the time since peak rate was achieved.
Repeater Configuration Menu Screens [13 - 24] (Navigation Key) When the Switch Configuration screen displays, the current screen settings are displayed for the first 12 ports. This field is used to step to the next screen for the same type of information for the next twelve ports, if available. (The number of ports available is dependent on the SmartSwitch model.) To navigate to the next screen, highlight the [xx-xx] field and press ENTER.
Chapter 1: Changes to Local Management Screens 1.15 802.1 CONFIGURATION MENU SCREEN The 802.1 Configuration Menu screen, Figure 1-15, provides access to the Switch Configuration, 802.1Q VLAN Configuration Menu, GARP Operation Status, GMRP Group Registrations, and 802.1p Priority Configuration Menu screens. To access the 802.1 Configuration Menu screen from the Device Configuration Menu screen, use the arrow keys to highlight the 802.1 CONFIGURATION MENU item and press ENTER. The 802.
802.1 Configuration Menu Screen 802.1Q VLAN CONFIGURATION MENU Displays only if the SmartSwitch has been configured to operate as an IEEE 802.1Q switch. When selected, this menu item opens the 802.1Q VLAN Configuration Menu screen. The IGMP/VLAN Configuration screen has been added to the 802.1Q VLAN Configuration Menu screen. The revised menu screen is shown in this supplement along with a description of how to use the IGMP/VLAN Configuration screen. Refer to Section 1.19 for details.
Chapter 1: Changes to Local Management Screens 1.16 SWITCH CONFIGURATION SCREEN The Switch Configuration screen, Figure 1-16, provides the basic setup options to make a switch operational in your network. To access the Switch Configuration screen from the 802.1 Configuration Menu screen, use the arrow keys to highlight the SWITCH CONFIGURATION menu item and press ENTER.
Switch Configuration Screen Age Time (Modifiable) Allows the user to set the amount of time (in seconds) that the SmartSwitch keeps an address in its switch table before discarding it. An address is automatically discarded when a valid frame is not received from that address within the time specified in the Age Time field. To change the Age Time field from the default value of 300 seconds, refer to Section 1.16.2. Port # (Read-Only) Lists each switched port on the device.
Chapter 1: Changes to Local Management Screens [1-8], [9-16], [17-24], [25-32], [33-40], or [41-48] (Navigation Key) When the Switch Configuration screen displays, the current screen settings are displayed for the first 8 ports. This field is used to step to another screen for the same type of information for ports 9 through 16, 17 through 24, 25 through 32, 33 through 40, and 41 through 48, if available. (The number of ports available is dependent on the SmartSwitch model.
Summary of VLAN Local Management 1.16.3 Setting (Enabling or Disabling) the Port Status To set the status of an interface (port), proceed as follows: 1. Use the arrow keys to highlight the Status field of the port. 2. Use the SPACE bar to toggle to either ENABLED or DISABLED. 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen. 4. Press ENTER. The message “SAVED OK” displays. 1.
Chapter 1: Changes to Local Management Screens 1.18 802.1Q VLAN CONFIGURATION MENU SCREEN To access the 802.1Q VLAN Configuration Menu screen from the 802.1 VLAN Configuration Menu screen, use the arrow keys to highlight the 802.1Q VLAN CONFIGURATION MENU item and press ENTER. The 802.1Q VLAN Configuration Menu screen, Figure 1-18, displays.
IGMP/VLAN Configuration Screen PORT FILTERING CONFIGURATION Used to set the switch to filter out inbound frames to prevent them from being forwarded by the switch out a particular port. This screen also lists the VLANs that have frames eligible to be transmitted out that port. Refer to your SmartSwitch device user’s guide for additional information.
Chapter 1: Changes to Local Management Screens IGMP is enabled or disabled by VLAN, not port by port. NOTE Certain versions of firmware will not allow the switch to be a querier. Please check your release notes for further information. Refer to RFC 2236, Section 8, for more information on IGMP.
IGMP/VLAN Configuration Screen Configuration ------------------IGMP Version: [ 2 ] Query Interval: 120 Query Response Time: 10 Interface Robustness: 2 Last Member Query Interval: 10 Statistics -----------Querier Address: 0.0.0.
Chapter 1: Changes to Local Management Screens Query Response Time (Modifiable) Used to enter the maximum query response time advertised in IGMPv2 general queries on this VLAN. This value is used in calculations for other timers. The default value is 10 seconds. The range of possible entries is 1 to 300 seconds. The value entered in this field cannot be bigger than the Query Interval. Interface Robustness (Modifiable) Allows tuning for the expected frame loss on a subnet.
IGMP/VLAN Configuration Screen VLAN ID (Selectable) Displays the Identifying number for the VLANs available to be modified. The information under Configuration and Statistics applies only to this VLAN ID number. Use the SPACE bar to step through all available VLAN IDs. IGMP State (Selectable) Displays the current state of the VLAN indicated in the VLAN ID field, which can be modified. Use the SPACE bar to step through the choices: ENABLED, DISABLED, ENABLE ALL, DISABLE ALL.
Chapter 1: Changes to Local Management Screens 6. Use the arrow keys to highlight the IGMP Version field. Then use the SPACE bar to select the proper IGMP version for the VLAN shown in the VLAN ID field. TIP When configuring IGMP, it is advisable to follow the IGMP configuration rules in RFC 2236 concerning switches and routers. 7. Use the arrow keys to highlight the remaining fields: Query Interval, Query Response Time, Interface Robustness, and Last Member Query Interval.
Priority/Multicast Configuration Menu Screen PORT PRIORITY CONFIGURATION ADVANCED PORT PRIORITY CONFIGURATION EXIT RETURN 27623-86 Figure 1-20 Priority/Multicast Configuration Menu Screen The Priority/Multicast Configuration Menu screen displays the following menu items: PORT PRIORITY CONFIGURATION Used to set the port default transmit priority (0 through 7) of each port for frames that are received without priority information in their tag header. For details, refer to Section 1.21.
Chapter 1: Changes to Local Management Screens 1.21 PORT PRIORITY CONFIGURATION SCREEN The Port Priority Configuration screen, Figure 1-21, is used to set the priority (0 through 7) on each port. A port receiving a frame without priority information in its tag header is assigned a priority according to the priority setting on the port. For example, if the priority of a port is set to 5, all frames received through that port without priority indicated in their tag header are classified as a priority 5.
Port Priority Configuration Screen The following describes each field of the Port Priority Configuration screen: Port # (Read-Only) Lists each switched port on the device. Priority (Selectable) Used to select the transmit priority of frames received without the priority indicated in their tag header. A priority of 0 through 7 (with 0 being the lowest priority and 7 the highest) can be selected for each port. All ports are set to the default value of “0” when the device is initialized.
Chapter 1: Changes to Local Management Screens 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen. 4. Press ENTER. The message “SAVED OK” displays and the setting is saved. 1.22 ADVANCED PORT PRIORITY CONFIGURATION SCREEN The Advanced Port Priority Configuration screen, Figure 1-22, is used to set the Priority/Queue Mapping and Priority Regeneration for a particular port or change the default port priority.
Advanced Port Priority Configuration Screen Priority Regeneration ---------------------------- Priority/Queue Mapping ------------------------------Priority TX Queue [0] 0 [0] 1 [0] 1 [1] 2 [0] 2 [2] 3 [0] 3 [3] 4 [1] 4 [4] 5 [1] 5 [5] 6 [1] 6 [6] 7 [1] 7 [7] Default Priority SAVE TX Priority RX Priority 0 [7] Port #: xxx PREVIOUS NEXT EXIT RETURN 2971_88 Figure 1-22 Advanced Port Priority Configuration Screen The following describes each field of the Advanced P
Chapter 1: Changes to Local Management Screens TX Priority (Selectable) Enables the frames with a certain RX priority to be changed to transmit according to a different TX priority (0 through 7). The following describes how the frames of learned traffic are handled. When a frame is received, it is checked to see if it has a priority. If it does, it is forwarded to the appropriate output port. If it does not, the frame is assigned the default RX priority and then forwarded to the appropriate output port.
Advanced Port Priority Configuration Screen 1.22.1 Setting the TX Mapping Queues To set the TX queue for frames with a particular priority, proceed as follows: 1. Use the arrow keys to highlight the Port # field. 2. Type in the number of the port to which the TX queue setting will be applied. 3. Use the arrow keys to highlight the Default Priority field. The screen refreshes and displays the current settings of the port in the Port # field. 4.
Chapter 1: Changes to Local Management Screens 5. Press the SPACE bar to step to the appropriate value, 0 through 7. The 0 selection is the lowest level TX priority value. 6. If more than one TX priority is to be changed, repeat steps 4 and 5 until all the appropriate TX priority settings are changed. 7. Use the arrow keys to highlight the SAVE command at the bottom of the screen. 8. Press ENTER. The message “SAVED OK” displays and the setting is saved. 1.22.
CHAPTER 2 LM SECURITY SCREENS FOR 2E43-51/2E43-51R DEVICES The information in this chapter replaces the information about the Repeater Configuration Menu and Repeater Port Configuration screens provided in the 2E43-51/2E43-51R SmartSwitch 2100 User’s Guide. 2.1 REPEATER CONFIGURATION MENU SCREEN The Repeater Configuration Menu screen, Figure 2-1, is used to access the Repeater Level Security Configuration, or Port Level Security Configuration screen.
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices The following introduces each screen that is accessible from the Repeater Configuration Menu screen. REPEATER LEVEL SECURITY CONFIGURATION Used to set the state of security of all ports on each connector, simultaneously. The ports can be set to receive all frames (NonSecure state), lock on the source address of the next frame received (LockOnNext), or lock on the address of the last frame received (LockedOnAddr). For details, refer to Section 2.
Repeater Level Security Configuration Interface 1 2 3 4 Security State Action On Intruder [NonSecure] [NonSecure] [LockOnNext] [LockedOnAddr] [DisablePort] [SendTrap] [DisablePort] [NoTrap] SAVE EXIT RETURN 2971_112w Figure 2-2 Repeater Level Security Configuration Screen The following section defines the fields on the Repeater Level Security Configuration screen. Interface (Read-Only) Indicates the interface connector (ENET 1 through 4) selected in the Interface field.
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices The port will lock down on the address that is currently configured in the Port Level Security Configuration screen (if one is entered), or on the source address of the last received frame. When a port is locked on an address, the device executes the actions selected in the Action On Intruder field (Port Level Security Configuration screen) when a frame is received that violates security.
Port Level Security Configuration Screen 4. To change the DisablePort setting to NoDisablePort, press the SPACE bar to toggle the setting. 5. Use the arrow keys to highlight the SendTrap field. 6. To change the SendTrap setting to NoTrap, press the SPACE bar to toggle the setting. 7. To change the security on all interface ports on more than one connector, repeat step 1 through step 6 for each connector. Then proceed to step 8 to save all settings at once. 8.
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices Port 1 2 3 4 5 6 7 8 9 10 11 12 Security State Action On Intruder [LockedOnAddr] [NonSecure] [LockedOnAddr] [LockOnNext] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NoDisablePort] [SendTrap] SAVE INTERFACE #: [1] Address [DisablePort] [SendTrap] [DisablePort] [SendTrap] [xx-xx-xx-xx-xx-xx] [00-00-00-00-00-00] [xx-xx-xx-xx-xx-xx] [00-00-00-00-00-00] [00-00-00-00-00-00] [00-00-00-00-00-00
Port Level Security Configuration Screen • LockOnNext – The next frame received by each port is examined to learn its source address. After the source address of a frame is learned on a port, it is now locked on that address and only those frames received with that same source address are allowed on that port. All frames received that do not have that same source address will cause the device to execute the actions selected in the Action On Intruder field.
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices INTERFACE # (Selectable) Used to select the front panel interface connector (ENET 1 to ENET 4) to which the port security settings will be applied. 2.3.1 Setting the Port Level Security To set the security for each repeater port on a connector, proceed as follows: 1. Use the arrow keys to highlight the INTERFACE # field. 2. Use the SPACE bar to step to the appropriate interface connector number (ENET 1 to ENET 4). 3.
Port Level Security Configuration Screen 13. Use the arrow keys to highlight the SAVE command. 14. Press ENTER. The message “SAVED OK” displays and all ports of the connector are set to the selected operating mode. 15. To change the security on a different interface connector, repeat step 1 through step 14 as needed.
Chapter 2: LM Security Screens for 2E43-51/2E43-51R Devices 2-10 Local Management Supplement
CHAPTER 3 LM SECURITY SCREENS FOR 2H23-50R/2H33-37R DEVICES The information in this chapter replaces the information about the Repeater Configuration Menu and Repeater Port Configuration screens provided in the 2H23-50R/2H33-37R SmartSwitch 2100 User’s Guide. 3.1 REPEATER CONFIGURATION MENU SCREEN The Repeater Configuration Menu screen, Figure 3-1, is used to access the Repeater Port Configuration, Module Level Security Configuration, or Port Level Security Configuration screen.
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices The following introduces each screen that is accessible from the Repeater Configuration Menu. REPEATER PORT CONFIGURATION Used to monitor the link status and current operating mode of each port on the 10-Mbps or 100-Mbps network of a front panel connector, and also turn each port on or off. For details, refer to Section 3.2. MODULE LEVEL SECURITY CONFIGURATION Used to set the state of security for each port of a connector, simultaneously.
Repeater Port Configuration Screen PORT# 1 2 3 4 5 6 7 8 9 10 11 12 SAVE NETWORK# 1 2 1 2 2 2 2 2 2 2 2 2 LINK STAT. CURRENT OPER. MODE No Link No Link Link No Link No Link No Link No Link No Link No Link No Link No Link No Link Unknown Unknown 10Base-T Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown Unknown SET ALL PORTS: [Auto-Neg] DESIRED OPER.
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices NETWORK # (Read-only) Indicates the network on the connector selected in the CONNECTOR field. Table 3-2 shows the association between the connector (CONN) and Networks on the device.
Repeater Port Configuration Screen PORT STAT. (Toggle) Used to enable (turn on) or disable (turn off) the port. To enable or disable the port, refer to Section 3.2.2. SET ALL PORTS (Selectable) Used to select operating mode for all the ports on the connector simultaneously. This field steps through the following selections: Auto-Neg., 10Base T, and 100Base-TX. To set all the ports to the same operating mode, refer to Section 3.2.3.
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices 3. Press ENTER to display the repeater port settings on that connector. 4. Use the arrow keys to highlight the PORT STAT. field of the repeater port being enabled or disabled. 5. Use the SPACE bar to toggle to the appropriate setting (Enable or Disable). 6. If setting more than one repeater port, repeat steps 4 and 5 for each one and then proceed to step 7. 7. Use the arrow keys to highlight the SAVE command. 8. Press ENTER.
Module Level Security Configuration 3.3 MODULE LEVEL SECURITY CONFIGURATION The Module Level Security Configuration screen, Figure 3-3, is used to set the state of security according to connector. All repeater ports on a connector can be set to receive all frames (NonSecure state), lock on the source address of the next frame received (LockOnNext) or the source address of the last frame received (LockedOnAddr).
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices The following section defines the fields on the Module Level Security Configuration screen. Connector (Read-Only) Indicates the connector. Refer to Table 3-3 for the connector (CONN)/repeater port relationship on the device.
Module Level Security Configuration • LockedOnAddr – The Security State of all ports on the specified connector are set to LockedOnAddr. This setting is for convenience, so that all ports on an interface connector can be set to LockedOnAddr at one time. Until the address is set at the repeater port level, the port will default to the locked on address of “00-00-00-00-00-00” as indicated by “XX-XX-XX-XX-XX-XX” in the address field shown in Figure 3-4.
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices 5. Use the arrow keys to highlight the SendTrap field. 6. To change the SendTrap setting to NoTrap, press the SPACE bar to toggle the setting. 7. To change the security on more than one connector, repeat steps 1 through 6 for each connector. Then proceed to step 8 to save all settings at once. 8. Use the arrow keys to highlight the SAVE command. 9. Press ENTER.
Port Level Security Configuration Screen Port Network 1 2 3 4 5 6 7 8 9 10 11 12 1 2 1 2 2 2 2 2 2 2 2 2 SAVE Security State Action On Intruder Address [LockOnNext] [DisablePort] [SendTrap] [NonSecure] [LockedOnAddr] [DisablePort] [SendTrap] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] [NonSecure] CONNECTOR #: [1] [00-00-00-00-00-00] [xx-xx-xx-xx-xx-xx] [00-00-00-00-00-00] [00-00-00-00-00-00] [00-00-00-00-00-00] [00-00-00-00-00-00] [00-00-00-00-0
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices Network (Read-only) Indicates the network to which the port is currently attached. Table 3-5 shows the association between the connector (CONN) and Network on the device.
Port Level Security Configuration Screen When a port is locked on an address, the device executes the actions selected in the Action On Intruder field when a frame is received that violates security. Action On Intruder (Toggle) Used to select the actions taken for the selected security state. There are two fields to select the actions. Both toggle to activate or deactivate the action. • DisablePort/NoDisable – DisablePort causes the switch to turn off the port that had a security violation.
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices 2. Use the SPACE bar to step to the appropriate connector (CONN) number. 3. Press ENTER to display the 12 repeater ports of the selected connector. 4. Use the arrow keys to highlight the Security State field for the desired repeater port. 5. Use the SPACE bar to step to the appropriate security level (NonSecure, LockOnNext, or LockedOnAddr). 6.
CHAPTER 4 GENERIC ATTRIBUTE REGISTRATION PROTOCOL (GARP) This appendix provides the following information: • Describes the switch operation when its ports are configured to operate under the Generic Attribute Registration Protocol (GARP) applications – GARP VLAN Registration Protocol (GVRP) and/or GARP Multicast Registration Protocol (GMRP).
Chapter 4: Generic Attribute Registration Protocol (GARP) The purpose of GVRP is to dynamically create VLANs across a switched network. When a VLAN is declared, the information is transmitted out GVRP configured ports on the switch in a GARP formatted frame using the GVRP multicast MAC address (01-80-C2-00-00-21). A switch that receives this frame, examines the frame, and extracts the VLAN IDs. GVRP then creates the VLANs and adds the receiving port to its tagged member list for the extracted VLAN ID(s).
GARP Multicast Registration Protocol (GMRP) Configuring a VLAN on an 802.1Q switch creates a static GVRP entry. The entry will always remain registered and will not time out. However, dynamic entries will time-out and their registrations are removed from the member list if the end station A is removed. This ensures that if switches are disconnected, or if end stations are removed, the registered information remains accurate.
Chapter 4: Generic Attribute Registration Protocol (GARP) 4.3 GARP OPERATION STATUS SCREEN The GARP Operation Status screen, Figure 4-2, is used to enable ports on the switch as GMRP- and GVRP-aware ports. The ports may be enabled one by one or all at the same time for GMRP and GVRP. To access the GARP Operation Status screen, use the arrow keys to highlight the GARP OPERATION STATUS menu item on the 802.1 Configuration Menu screen and press ENTER. The GARP Operation Status screen displays.
GARP Operation Status Screen GVRP (Toggle) Sets the port to operate as a GVRP-aware port. The setting is only valid if the GVRP Protocol field near the bottom of the screen is set to Enable. The GMRP field setting toggles between Y (yes) and N (no). The default is “Y”. To set the port, refer to Section 4.3.1. Set All Ports (Selectable) Sets all ports to the same setting by selecting one of the following: • GMRP Enable All – Sets all ports as GMRP-aware ports. All ports are set to Y under GMRP.
Chapter 4: Generic Attribute Registration Protocol (GARP) GVRP Protocol (Toggle) Enables or disables the GVRP Protocol on the switch. When set to Enable, all port settings are valid for GVRP enabling those ports to send/receive frames to other GVRP-aware switches. Disable makes the port settings invalid. The default setting is “Disable”. To enable or disable the protocol, refer to Section 4.3.2. 4.3.1 Setting a Port to Operate in GMRP or GVRP To set a port to be a GMRP or GVRP aware port.
GMRP Configuration Screen 3. Press ENTER. 4. Use the arrow keys to highlight the SAVE command at the bottom of the screen. 5. Press ENTER. The message “SAVED OK” displays. 4.4 GMRP CONFIGURATION SCREEN The GMRP Configuration screen, Figure 4-3, is used to set the GMRP operation mode of each port. To access the GMRP Configuration screen, use the arrow keys to highlight the GMRP GROUP REGISTRATIONS menu item on the 802.1 Configuration Menu screen and press ENTER. The GMRP Configuration screen displays.
Chapter 4: Generic Attribute Registration Protocol (GARP) Mode (Selectable) Select one of the following four modes of operation: • Use GMRP Filter Unreg – Do not forward multicast addressed frames out this port that have an unregistered multicast address. • Forward All Groups – Regardless of multicast address registration, send all multicast addressed frames out this port.
GMRP Configuration Screen 4.4.2 Setting a Mode for All Ports The modes of operation are the same as the ones described in Section 4.4.1, except that all ports are affected. To set all the ports to operate in one mode, proceed as follows: 1. Use the arrow keys to highlight the Set All Ports field. 2. Press the SPACE bar to select one of the following modes of operation: • Use GMRP Filter Unreg • Forward All Groups • Filter All Groups • Use GMRP Forward Unreg 3. Press ENTER. 4.
CHAPTER 5 NETWORK TOOLS This chapter introduces the “cdp” command and shows how it affects the Network Tools Help screen. The cdp command is an addition to the built-in commands listed in your SmartSwitch user’s guide. 5.1 NETWORK TOOLS The Network Tools function resides on the platform firmware and allows the user to access and manage network devices. Figure 5-1 shows the updated Network Tools Help screen.
Chapter 5: Network Tools Welcome to Network Tools -> help Commands Available to the Built in Commands: bridge ping traceroute defroute reset soft_reset telnet link_trap atm_stp_state cdp stpStandby arp netstat show SPECIAL: done, quit, or exit - Exit from the Network Tools. For help with a specific command, type 'help '. -> 090829 Figure 5-1 Network Tools Help Screen The Network Tools functions are performed using a series of commands.
Network Tools cdp Description: Allows management of Cabletron Discovery Protocol (CDP) on this device. This protocol is used by SmartSwitch device to discover other neighboring network devices and establish the topology of the network fabric. This protocol can also be used by the SmartSwitch device to propagate specific information to neighboring network devices.The user may enable, disable, or see the current status of CDP.
APPENDIX A ABOUT IGMP This appendix provides the following information: • IGMP Overview • Supported Features and Functions • Detecting Multicast Routers To configure the SmartSwitch device for IGMP operation, refer to Section 1.19 for instructions. A.1 IGMP OVERVIEW IGMP is a multicast protocol used by routers. This protocol is supported by Cabletron Systems SmartSwitches when operating in the 802.1Q mode to “snoop” the IGMP frames.
Appendix A: About IGMP • Supports stand alone multicast servers only if a router is present on the network. • Multicast forwarding rate is dependent on the number of ports to which the multicast stream is forwarded. More ports degrade the performance. • Supports IGMP version 1 and 2 only. Default is version 2. • Ports that are directly connected to routers are discovered dynamically through snooping for routing protocols. • IGMP is enabled or disabled per VLAN, and not per port.
Detecting Multicast Routers There are many multicast routing protocols that the switch supports. These include the following: • PIM version 1 and 2 • CBT (core based trees) • MOSPF • DVMRP The routing protocols are detected as follows: • All the multicast routing protocols have a destination address of 01-00-5E. • DVMRP and PIM version 1 run over IGMP. If the IGMP frame type is not a REPORT, QUERY, OR LEAVE, then the frame is assumed to be one of these.
INDEX Numerics 802.1D switching mode hierarchy of 1-3 802.
Index H O Hierarchy 802.1D switching mode 1-3 802.
Index Repeater Port Configuration screen (2Hxx) connector # 3-5 current oper. mode 3-4 desired oper. mode 3-4 link stat. 3-4 network # 3-4 port # 3-3 port stat. 3-5 set all ports 3-5 Repeater Ports (2Hxx) enabling or disabling of 3-5 S Screen Repeater Port Configuration screen (2Hxx) 3-2 Screen Format 1-5 Screens 802.1 Configuration Menu screen 1-38 802.
Index MAC address 1-41 number of ports 1-40 port # 1-41 port status 1-43 selecting the STA 1-42 status 1-41 switch address 1-40 type of STA 1-40 System Resources Information screen CPU type 1-8 current switch utilization 1-9 DRAM installed 1-9 FLASH memory installed 1-8 NVRAM installed 1-9 peak switch utilization 1-9 reset peak switch utilization 1-9 V VLAN configuration of 1-39 Local Management for 1-39 VLAN Local Management summary of 1-43 VLAN Redirect Configuration screen destination port 1-32 frame fo