Change the following line:
@ACC_SPEC: ÒPasteÓ = ÒShift<Key>Insert
to
@ACC_SPEC: ÒPasteÓ = ÒShift<Key>KP_Insert
Change the following line:
@ACC_SPEC: ÒCopyÓ = ÒCtrl<Key>Insert
to
@ACC_SPEC: ÒCopyÓ = ÒCtrl<Key>KP_Insert
Problem 2: On a Windows NT workstation you cannot close a window
before the application has completed processing. The window close event
is not immediately processed on an NT workstation.
Solution: Wait until the application has completed processing.
Problem 3: On the Windows NT platform, blank images appear when you
create a TIFF file using Wang’s Imaging utility (included with Windows NT).
This utility produces TIFF files using a non-standard extension to the TIFF
specification, which is not supported by SPECTRUM.
Solution: SPECTRUM supports TIFF files created by utilities that
conform to the standard TIFF specification. Utilities which convert BMP
files to TIFF format files are available as freeware and shareware.
Problem 4: In the Stack Link View on the Windows NT platform, the pipe
connecting the two model is split horizontally with black on top and green
on the bottom.
Solution: This is a visual problem only derived from bug in Neuron Data’s
toolkit. This problem will be corrected in a future release of SPECTRUM.
Problem 5: On the Windows NT platform, when you enable “See contents
of windows while dragging” in the Control Panel, the display and
performance of various SPECTRUM applications (i.e., SpectroGRAPH and
Model Type Editor) may be affected.
Solution: Avoid enabling opaque window dragging by not turning on