Specifications

Table Of Contents
Corrected and Known Anomalies
SPECTRUM Installation Program
Software Release Notes Page 97
Problem 19: On the Windows NT platform, you are not allowed to perform
an installation into a directory that contains a space. You are forced to
install into the win32app as the default directory.
Solution: This problem will be addressed in a future release of
SPECTRUM.
Problem 20: On Windows NT, when you install SpectroSERVER and
external components over an existing SpectroGRAPH installation, the
landscape handle does not get set and the installation fails. You receive
error message similar to:
Not Retrieving record SM-GNSW for product SG
....
**Error during setting of landscape handle
Solution: In the Component Selection, click Selection Filters, click
SAME, and click, OK. Then click, Select All and continue with the
installation. This problem will be corrected in a future release of
SPECTRUM.
Problem 21: During a SPECTRUM installation on Windows NT, if you
decide to Cancel the Adobe Acrobat installation, the installation process is
aborted instead of completing. PATHS within the Environmental setting
are not set. After re-booting, you receive a message which says:
SCP.exe - Unable to locate DLL.
Solution: Make certain that you don’t check the Acrobat Reader install
checkbox prior to running the install process unless you determine you
really need it. Once started, do not cancel out of the process and let the
installation complete.
Problem 22: When installing SPECTRUM on a Windows NT workstation
containing MKS, SPECTRUM installation will fail.
Solution: If your workstation has MKS, uninstall it prior to installing
SPECTRUM. If your system requires that you have MKS, move the MKS in
the install path to the very end of the path.