User`s guide
Monitoring and Managing the ATX
4-11
• Whether a topology change is currently in progress.
[stTopChange]
• If a topology change is in progress then this is the time since the
topology change was initiated. If a topology change is not in
progress then this is the time since a topology change was
finished. [stTopChangeTime]
4.2 MODULE STATUS AND STATISTICS
The status and statistics described in this section are applicable to
all Input/Output Modules.
• Whether the module's temperature is too hot. [hwTempOK]
• Results of diagnostics, when diagnostics were last performed on
the module (usually power-up). Possible values: diagnostics
failed, diagnostics still running, diagnostics passed.
[hwDiagStatus]
• Status code for the diagnostics that was last run on the module.
[hwDiagCode]
• Whether the module is currently executing its operational
software. [hwInuse]
• The manufacturing information for this module which includes
serial number, hardware revision level, and serial number.
[hwManufData]
4.2.1 End-node Status and Statistics
The ATX keeps statistics on end-nodes on attached networks,
allowing you to monitor the traffic flows from those networks.
Status and statistics on each end-node, recorded in the Bridge
Address Table, follows:
• The port through which this station is connected to the ATX
(only valid for dynamically learned addresses and unique
addresses for ATX's agent software).