Specifications

ATM BW Manager Port Pool Trap Management Table View
Device Management Page 115 SmartSwitch 9000/9500 Series
Opens the Nodal Timer Information View
(Page 115).
Opens the SVCC Variable Information View
(Page 116).
Nodal Timer Information View
Access: From the Nodal Map Information view, click the
Node Timer Information button.
This view provides nodal timer information in the
following fields.
PTSE Hold
The initial value for the PNNI Topology State
Element (PTSE) hold down timer that is used by
the given node to limit the rate at which it can re-
originate PTSEs. The value must be a positive
non-zero number in units of 100 milliseconds.
HelloHoldDown
The initial value for the Hello hold down timer
that is used by the given node to limit the rate at
which it sends Hellos. The value must be a
positive non-zero number in units of 100
milliseconds.
HelloInterval
The initial value for the Hello timer, in seconds. In
the absence of triggered Hellos, this node will
send one Hello packet on each of its ports on this
interval.
Inactivity
The value for the Hello inactivity factor that this
node will use to determine when a neighbor has
gone down. The default value is 5.
LinkInact
The number of seconds a node will continue to
advertise a horizontal (logical) link for which it
has not received and processed an LGN horizontal
link information group. The default value is 120.
Refresh
The initial value for the Refresh timer that this
node uses to drive (re-)origination of PTSEs in the
absence of triggered updates. The default value is
1800 seconds.
LifetimeFactor
The value for the lifetime multiplier, expressed as
a percentage. The result of multiplying the value
for Refresh by this value is used as the initial
lifetime that this node places into self-originated
PTSEs.
Node Timer Information
Svcc Variable Information