Specifications

ATM Interface Views
Device Management Page 119 SmartSwitch 9000/9500 Series
Neighbor Address
The IP address of the neighbor system connected
to the far end of this interface to which an NMS
can send SNMP messages.
Neighbor If Name
The textual name of the interface of the neighbor
defined in the Neighbor Address field.
TC Sublayer Table View
Access: From the Icon Subviews menu for the Switch
Application icon, select Interface > TC Sublayer.
This view provides the following Transmission
Convergence (TC) sublayer alarm and event
information.
IF Index
The interface number.
OCD Events
The number of times the Out of Cell Delineation
(OCD) events occur. An OCD event occurs when
seven consecutive ATM cells have Header Error
Control (HEC) violations. A high number of OCD
events may indicate a problem with the TC
sublayer.
TC Alarm State
Indicates if there is an alarm present for the TC
sublayer. Failure indicates that a Loss of Cell
Delineation (LCD) state has been declared for the
TC sublayer. Transition from Failure to No
Alarm occurs when six consecutive ATM cells are
received with a valid Header Error Check (HEC),
followed by about 10 seconds of acceptable signal.