Specifications
ATM VCL Statistics Table View
Device Management Page 129 SmartSwitch 9000/9500 Series
VCL Statistics Table View
Access: From the Icon Subviews menu for the Switch
Application icon, select VCL Statistics.
This table contains all statistics counters per
VCL. It is used to monitor the usage of the VCL in
terms of incoming cells and outgoing cells.
Interface
The interface number.
VCL VPI
The VPI value of the VCL.
VCL VCI
The VCI value of the VCL.
Total Cells In
The total number of valid ATM cells received by
this VCL including both CLP=0 and CLP=1 cells.
The cells are counted prior to the application of
the traffic policing.
Clp0 Cells In
The number of valid ATM cells received by this
VCL with CLP=0. The cells are counted prior to
the application of the traffic policing.
Total Discards
The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1.
Total Cells Out
The total number of valid ATM cells transmitted
by this VCL. This includes both CLP=0 and CLP=1
cells.
Clp0 Cells Out
The total number of valid ATM cells transmitted
with CLP=0 by this VCL.
Tagged Outs
The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VCL.
Switched Virtual Channel
Cross Connect Table View
Access: From the Icon Subviews menu for the Switch
Application icon, select SVC VC Cross Connect.
The ATM SVCC Cross-Connect table. A bi-
directional VC cross-connect between two
switched VCLs is modeled as one entry in this
table. A Soft PVCC cross-connect, between a soft
permanent VCL and a switched VCL, is also
modeled as one entry in this table.
Index
A unique value to identify this SVCC cross-
connect.