Specifications

ATM Signalling Monitoring Table View
Device Management Page 134 SmartSwitch 9000/9500 Series
The following cause values are monitored by this
counter. See Table 39 for applicable cause values
and meanings. (Note: These cause values apply to
both UNI3.0 and UNI3.1 unless otherwise stated):
Calling Party
Number of Calling Party Events detected on this
interface. This counter monitors error events that
occur due to the originating user doing something
wrong. This counter is incremented when a
RELEASE, RELEASE COMPLETE (only when not
preceded by a RELEASE message for the same
call), ADD PARTY REJECT, or STATUS message
that contains one of the following cause code
values is received. See Table 40 for applicable
cause values and meanings. (Note: These cause
values apply to both UNI3.0 and UNI3.1):
Table 39: Message Errors
Cause Value Meaning
10 VPCI/VCI unacceptable (UNI3.0 only).
36 VPCI/VCI assignment failure (UNI3.1
only).
81 Invalid call reference value.
82 Identified channel does not exist.
89 Invalid endpoint reference.
96 Mandatory information element is
missing.
97 Message type non-existent or not
implemented.
99 Information element non-existent or
not implemented.
100 Invalid information element contents.
101 Message not compatible with call
state.
104 Incorrect message length.
111 Protocol error, unspecified.
Table 40: Calling Party
Cause Value Meaning
28 Invalid number format (address
incomplete).
43 Access information discarded.
57 Bearer capability not authorized.
65 Bearer capability not implemented.
73 Unsupported combination of traffic
parameters.
78 AAL parameters cannot be supported
(UNI3.1 only).
91 Invalid transit network selection.
93 AAL parameters cannot be supported
(UNI3.0 only).