Specifications

Device View Secondary Address Panel
Device Management Page 35 SmartSwitch 9000/9500 Series
- Yellow - over current, over voltage, or
under voltage.
Diag Pwr Bus - field does not function at this
time. A future version of firmware will include
this functionality.
INB Term - displays the voltage of the
termination power bus. The termination
power bus provides power to the INB
termination cards within the chassis.
- Green - power normal.
- Yellow - over current, over voltage, under
voltage, or over power.
UPS/Battery
Status - displays the UPS’s operational
status. Below are a list of colors and
conditions associated with this field.
- Red - overload, low battery, or replace
battery.
- Blue - no UPS.
- Green - on line.
- Yellow - calibration running.
Run Time - displays the estimated remaining
run time in minutes. You can query the UPS
when operating on-line, bypass, or on-battery
modes of operation. The run time estimate is
based on available battery capacity and
output load.
UPS Details View
Access: From the Icon Subviews menu for the
UPS/Battery section of the Chassis Device View, select UPS
Details.
This view provides the following information on
the UPS battery.
Index
An unique value that identifies a particular UPS.
Name
The name of the UPS.
Model Type
The model type of the UPS.
Battery Capacity
The UPS’s remaining battery capacity expressed
as a percent of the fully charged condition. The
value of this object is the actual percentage
multiplied by 10.
Operational Status
The operational status of the UPS. Possible
entries are: on-line, on-battery, overloaded,
low battery, replace battery, smart boost,
sleep, and run time calibration running.