Specifications

FDDI FDDI Station Table View
Device Management Page 62 SmartSwitch 9000/9500 Series
Error Threshold
The threshold value within the alarm timebase
that, once the percentage of errors per good
packet is exceeded, generates an error alarm.
Error Source
This area of the Repeater Configuration view
provides a series of buttons allowing you to select
the types of errors to include in the error sum.
The selectable error types are as follows:
CRC
The number of packets received by the module
with bad Cyclical Redundancy Checks (CRCs).
Runts
The number of runt packets received by the
module. A runt packet is one byte less than the
standard Ethernet frame of 64 bytes (not
including preamble).
OOW_Colls
The number of collisions out of the standard
window (51.2ยตs) due to a network problem.
Alignment
The number of misaligned packets detected by
the module.
No_Resource
The number of times the module ran out of
resources (i.e., lack of buffer space) and could not
accept packets.
Giants
The number of giant packets received by the
module. A giant packet exceeds 1518 bytes (not
including preamble).
FDDI Station Table View
Access: From the Icon Subviews menu for the FddiMAC
Application icon, select Fddi Station List.
This view displays the configuration of the FDDI
ring, basic information about the devices in the
ring, and FDDI network.
Use these buttons to perform the functions listed
in the contents of the Station Table.
This button affects the display of the station
addressed, toggling between MAC (Physical) and
Canonical (Ethernet). This button displays the
format NOT currently selected.
Update, Print, Sort and Find
MAC/Canonical