Specifications

Token Ring Token Ring Station Table View
Device Management Page 82 SmartSwitch 9000/9500 Series
Station Alarms Dialog Box
Access: From the Token Ring Station Alarm Threshold
view, click the Stations Alarms button.
The Station Alarms dialog box allows you to read,
display, and modify the alarm settings for a single
station or list of stations. The list displays the
stations that were on the ring at the time the
dialog box was opened. You can read and modify
the settings to a valid station that does not appear
in the list and was added after opening the view
by entering its address in the Station field.
Table 25: Non-Isolating Errors Pie Chart
Statistic Definition
Lost Frames The total number of times a station has
had its Token Ring Rotation (TRR) timer
expire trying to transmit.
Congestions The total number of times a station
recognizes a frame addressed to it, but the
station has no available buffer space.
Frame Copied The total number of times a station
recognizes a frame addressed to it, and
detects that the FS field A bits are set to 1.
Token The total number of times the station
acting as active monitor recognizes an error
condition requiring a token be transmitted.
Frequency The total frequency errors on this ring.
Table 26: Isolating Errors Pie Chart
Statistic Definition
Line The number of line errors that have
occurred on this ring.
Burst The number of burst errors that have
occurred on this ring.
A/C The number of address/copied errors
that have occurred on this ring.
Abort
Sequence
The number of abort sequences
transmitted on this ring.
Internal The number of internal errors detected
by a station on this ring.