Installation guide

20-7
Messages 300 399
Local -333- Invalid terminal type specified
Explanation: The terminal type you specified is invalid.
Action: Enter a valid terminal type: ANSI, UNKNOWN, or VTnnn where nnn is a
number between 10 and 999. For more information, refer to the Network Access Software
Management Guide.
Local -345- Listener 23 cannot be type RAW TCP
Explanation: Listener 23 cannot be used as a RAW TCP connection.
Action: Use another TCP port. For more information, refer to the Network Access
Software Management Guide.
Local -346- Remote Console cannot be type RAW TCP
Explanation: A RAW TCP listener cannot have Console as one of its ports.
Action: Use another port. For more information, refer to the Network Access Software
Management Guide.
Local -347- Listener is not type RAW TCP.
Explanation: The listener port numbers specified are not of the type RAW.
Action: Recheck the listener port numbers.
Local -350- Invalid Internet address
Explanation: The Internet address is not valid.
Step Action
1 Enter the following command on your access server to change the Internet address.
Substitute the Internet address for 195.1.1.78:
Local> DEFINE INTERNET ADDRESS 195.1.1.78
Note: Use the SET INTERNET ADDRESS command only if there is no defined
Internet address; otherwise, the access server rejects the command.
2 Initialize the access server. For more information on the INITIALIZE command,
refer to the
Network Access Software Commands Reference Guide.