Installation guide

Messages 800 899
25-2
Local -803- TN3270: initialization failed setting port
Explanation: The TN3270 session failed to be initialized due to a temporary resource
condition at the port.
Action: Restart the session. If this action fails to correct the problem, refer to Chapter 29
for service information.
Local -804- TN3270: initialization failed; insufficient memory
Explanation: A TN3270 session could not be started due to insufficient memory.
Action: Enter the SHOW SERVER STATUS command. To free memory space, verify the
access server memory usage. See the section Verify Access Server Memory Usage
(Chapter
2)
, and disconnect any unused sessions, then restart the session.
Local -805- TN3270: screen output buffer exceeded
Explanation: An internal output buffer could not accommodate output data destined for
the port device.
Action: Restart the session. If this action fails to correct the problem, contact your IBM
support staff to determine the appropriate action to prevent the application from sending a
buffer address outside the limit for a 3278 Model 2.
Local -806- TN3270: invalid TN3270 buffer address from host
Explanation: The host requested operation in an area of terminal screen emulation that is
out of bounds.
Action: Restart the session. If this action fails to correct the problem, refer to Chapter 29
for service information.
Local -807- TN3270: escape sequence from keyboard too long
Explanation: An internal software error was detected when the TN3270 session
attempted to initialize keymaps.
Action: Change the keymap definition that caused the error and restart the session.
Local -808- TN3270: inconsistent Telnet protocol event received
Explanation: The access server received a Telnet protocol event from the host that is
inconsistent with the Telnet protocol state needed to maintain a TN3270 session.
Action: Inform your IBM host system manager.