The SmartSwitch Router includes a Control
Module and Line Modules as described below:
Control Module
The control module is used to manage the line
modules. It is responsible for maintaining route
table and bridge table information, SNMP
management, and system housekeeping. It has a
200 MHz R5000 processor that runs spanning
tree algorithms and routing protocols such as
RIP, BGP4 and OSPF. It has two front panel
interfaces for side and out-of-band management.
Table capacity is based on the amount of memory
within the control module. Configurations may be
either 64 MB for up to 50,000 routes, or 128 for
up to 100,000 routes.
Line Modules
The line modules determine the number of flows
that a SmartSwitch Router can handle. Line
modules with 4 MB of memory can support up to
500,000 L4 flows, with 16 MB they can support
up to 2,000,000 flows. The line modules store
bridge table and MAC address information from
the L2 table on the control module.
Table 1 through Table 3 list the line modules that
are supported:
Table 1: Cabletron Devices
Device Model Type MM
SSR-32000 SmartSwRtr32 SM-CSI1091
SSR-8600
SSR-8000
SSR-3000
SSR-2100
SSR-2000
SSR-1200
IA-1100
SmartSwRtr SM-CSI1091
Table 2: Enterasys Devices
Device Model Type MM
X-Pedition ER16 XPedER16SwRtr SM-ENT1005
X-Pedition 8600
X-Pedition 8000
X-Pedition 2100
X-Pedition 2000