Specifications

CyberSWITCH 200 Series and 400 Events and Alarms
Event and Alarm Messages CyberSWITCH Devices (200 Series and 400)
4-8 Management Module Guide
CsEvFormat/Event000d011e
{d “%w- %d %m-, %Y - %T”} - A fan in
the system’s chassis has failed or is
operating at an abnormal RPM rate,
has been detected by {m} ({t}). (event
[{e}])
CsPCause/Prob000d011e
Either one or more fans in the fan tray
assembly have failed, or the fan tray has
been removed. The situation is not critical,
but temperature warm and temperature
hot traps may follow. If the temperature
traps have appeared in the alarm log, the
failure should be addressed before
overheating damages the device.
CsEvFormat/Event000d011f
{d “%w- %d %m-, %Y - %T”} - A fan in
the system’s chassis has resumed
normal operation, has been detected
by {m} ({t}). (event [{e}])
CsPCause/Prob000d011f
The problem previously detected with the
fan assembly has been corrected and the
unit is now functioning normally.
CsEvFormat/Event000d0121
{d “%w- %d %m-, %Y - %T”} -
Broadcast threshold exceeded {I 1}
total packets in {I 3} seconds on the
module in slot {I 5} of {m} ({t}). (event
[{e}]
CsPCause/Prob000d0121
MODULE BROADCAST THRESHOLD
EXCEEDED
This trap will be generated when the
broadcast (packets per time interval) has
been exceeded for the given module.
CsEvFormat/Event000d0122
{d “%w- %d %m-, %Y - %T”} -
Broadcast threshold exceeded {I 1}
total packets in {I 3} seconds on port {I
7} on the module in slot {I 5} of {m}
({t}). (event [{e}])
CsPCause/Prob000d0122
PORT BROADCAST THRESHOLD
EXCEEDED
This trap will be generated when the
broadcast (packets per time interval) has
been exceeded for the given port.
CsEvFormat/Event000d0125
{d “%w- %d %m-, %Y - %T”} - System
Voltage Low condition has been
detected by {m} ({t}). (event [{e}])
CsPCause/Prob000d0125
The internal 5 volt line of the system is
low. The voltage low condition indicates
that either the power supplies are failing
or there is not enough power available to
the host modules. This is a serious
condition and should be addressed
immediately.
CsEvFormat/Event000d0126
{d “%w- %d %m-, %Y - %T”} - System
Voltage Normal condition has been
detected by {m} ({t}). (event [{e}])
CsPCause/Prob000d0126
The problem with the internal 5 volt line
of the system has been corrected. The
system voltage condition has returned to
normal.
Table 4-1. CyberSWITCH 200 Series and 400 Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message