Specifications
9032231 E1 Event and Alarm Messages
4-9
CyberSWITCH 200 Series and 400 Events and Alarms
CsEvFormat/Event000d0127
{d “%w- %d %m-, %Y - %T”} - An
EPIM has been removed from port {I
3} on module in slot {I 1} of {m} ({t}).
(event [{e}])
CsPCause/Prob000d0127
An Ethernet Port Interface Module
(EPIM) has been physically removed.
CsEvFormat/Event000d0128
{d “%w- %d %m-, %Y - %T”} - An
(EPIM) has been inserted into port {I
3} on module in slot {I 1} of {m} ({t}).
(event [{e}])
CsPCause/Prob000d0128
An Ethernet Port Interface Module
(EPIM) has been physically inserted.
CsEvFormat/Event000d0129
{d “%w- %d %m-, %Y - %T”} - Traffic
threshold, {I 1} packets per {I 3}
seconds, exceeded on the repeater
network {I 5} of {m} ({t}). (event [{e}])
CsPCause/Prob000d0129
The device(s) attached to this channel may
have an application level problem. The
attached devices may be operating
properly, but the application requires a
large amount of network bandwidth. If the
application requires a large amount of
bandwidth, a bridge or router may be used
to logically separate various network
segments. This trap indicates that module
or port level thresholds on this repeater
channel are needed to pinpoint high
bandwidth users.
CsEvFormat/Event000d0130
{d “%w- %d %m-, %Y - %T”} - Error
threshold exceeded. An error
threshold, of {I 1}% total packets in {I
5} seconds, exceeded on repeater
network {I 7} of {m} ({t}). (event [{e}])
CsPCause/Prob000d0130
A user defined threshold has been
exceeded on this channel. This threshold
could indicate that a malfunctioning
device is present on this channel or that a
cable fault exists. A module or port level
threshold should be set to further
troubleshoot to the offending node.
Table 4-1. CyberSWITCH 200 Series and 400 Events and Alarms (Continued)
Message in the Event Log
Alarm Manager Probable Cause
Message