Multiple Management Modules
Note: Ignore fields enclosed in red boxes or error messages
warning of blank table entries. These indicate that
the required data was not obtainable from the
device, and they occur when the device firmware
does not support these data requests from
SPECTRUM.
Known Anomalies
Item Description Solution
1 On some model types, SPECTRUM does
not recognize manual changes to
environmental variables until the
SPECTRUM Control Panel is shut down
and reopened. For example, this is true
with CIMPATH when used to launch
Compaq Insight Manager,
ROAMEXCPATH when used to launch an
application for RoamAbout, CVIEW when
used to launch Cisco Works on some
Cisco devices, and COPPEREXCPATH
when used to launch Copper View
Element Manager for Copper Mountain
devices.
Restart the SPECTRUM Control Panel
after making this type of change.
2 Some read/write attributes in
RFC1315App can not be changed on
some device models.
Some manufactures do not implement
all of the attributes from RFC1315 as
read/write, as is specified by the
standard, but rather as read-only. This
can cause errors when trying to write to
these attributes, as writing to them is
prohibited by the firmware.