Specifications

SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.5.1
Page 22
Document 0743
Revision 14
June 2002
5 On Windows NT, when printing an alarm
report with multiple probable causes
from the Alarm Manager, its possible:
- The second listed probable cause (not
shown in Alarm Manager without
scrolling down) bleeds through the
printout outside of the tab.
- A selected alarm prints black, making it
impossible to read.
- The probable cause column title bleeds
through the scroll bar on the printout.
Use a Level 2 Postscript printer.
6 When you run Alarm Manager (in a
distributed environment) against a
SpectroSERVER that does not have all
model types linked, but is modeling
another landscape where they are
linked, these model types do not display
in the Alarm Manager: Filter dialog’s
Model Type list. However, any alarms on
models of those model types display in
the alarm list.
Make sure the server has all model types
(in the distributed environment) that
need to display in the model type list.
7 The Alarm Manager shuts down if you try
to change column sizes while the model
list is updating.
Wait until the model list completes
updating, then resize the columns. This
is related to a third-party integration;
the vendor currently has this issue under
review.
8 If the Model menu or the Icon Subviews
menu is open when the device is
removed from the view (e.g., the alarm
is cleared or the device is destroyed),
Alarm Manager shuts down if you try to
access either menu.
If the Model or Icon Subviews menu is
open when the device is removed from
the view, close the menu (release the
right mouse button or click elsewhere in
the view), then reopen the menu for the
newly selected item.
Aprisma is working with a third-party
component vendor to investigate a fix or
workaround for this issue.
9 On Windows NT, applications can appear
to freeze if you post a menu while an
error dialog is displayed. For example, if
you post the Icon Subviews menu and
you get an error dialog stating
SpectroSERVER has lost its connection,
the application appears to freeze.
Press the <Esc> key.
Known Anomalies: Enterprise Alarm Manager (EAM)
Item Description Solution