Specifications

SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.5.1
Page 58
Document 0743
Revision 14
June 2002
Known Installation Anomalies: SPECTRUM Web Operator
Item Description Solution
1 On Windows NT, the
%WINDIR%\system32\MSVCRT.DLL file
needs to be version 6.0 or higher. If not,
you receive the following error message
during the installation:
The procedure entry
point_lc_collate_cp could not be
located in the dynamic link library
MSVCRT.dll
To resolve this issue:
1. On your desktop, close all programs.
2. Stop all NT services by selecting
Start > Settings > Control Panel >
Services; then select each service and
click Stop.
3. Under the NT Task Manager’s
Processes tab, select EXPLORER.EXE;
then click End Process. This closes the
desktop Explorer, but leaves the NT Task
Manager running.
4. Select Applications > New Task.
5. Enter cmd in the open field. This runs
the command prompt (cmd.exe)
window.
6. Close the Task Manager Window.
7. At the command prompt, navigate to
%WINDIR%\system32 and rename
msvcrt.dll to msvcrt.dll.old.
8. At the command prompt, copy
%TEMP%
<directory name>
\
Windows\MSVCRT.DLL to
%WINDIR%\system32, where
<directory
name>
is the directory in which you tried
to install Web Operator (for example,
I1019825635).
9. Reboot your workstation and start the
Web Operator installation.
Corrected Model Browser Anomalies: SPECTRUM Web Operator
Item Description
1 When you click the Destroy Pipe button without selecting a model, you now receive
the error message: Operation Failed.