Specifications

SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.5.1
Page 86
Document 0743
Revision 14
June 2002
Cabletron SFSmartCell Switch
Management Module Information
MM Part Number Device(s) Firmware Version
SM-CSI1073 SmartSwitch 9A656_04
SmartSwitch 9A686_04
2.04.09
02.02.0
Known Anomalies
Item Description Solution
1 The Clocking to Mother Board field is
empty in the device’s SecureFast Smart
Cell Switch Interface Configuration Table
view. The same field is red-boxed for
devices using the 02.02.03 firmware.
This is a firmware issue.
2 AutoDiscovery does not resolve the port
connection for the 9A656-04. Although
you can see a connection between the
switches, you must resolve the port
manually.
To find the port, read the
atmInterfaceMyNeighborIpAddress
and atmInterfaceMyNeighborIfName
attributes from the ATM MIB. (Not all
devices fill in
atmInterfaceMyNeighborIfName with
the port number.) The devices should
show atmInterfaceMyNeighborIfName
with the port number and not the
ifDescr value. This attribute is read/
write. Change this name to another
interface name to show two ports on one
switch connected to two ports on
another switch.
3 The ANIM Configuration view incorrectly
identifies a 3-port 155Mbps SC ANIM as
a 2-port 622Mbps SC ANIM.
This is a firmware issue.