Installation guide

CSX200 Installation Guide 4-1
4
Installation
This chapter shows you how to connect your CSX200 to the network. Ensure that the network
meets the guidelines and requirements outlined in Chapter 3, 10BASE-T LAN Requirements,
before installing your CSX200.
Unpacking the CSX200
Remove the shipping material from the box and carefully remove the CSX200. Visually inspect
the CSX200. If there are any signs of damage, contact Cabletron Systems (see the Getting Help
section) immediately. Read the CSX200 Release Notes included in the shipping box.
Installation Guidelines
Installation sites must meet the requirements listed below:
A properly grounded power receptacle must be within seven feet of the location.
In a shelf installation, the shelf must be able to support 13.6 kg (30 lb) of static weight for each
device on the shelf.
You must maintain a temperature of between 5°C (41°F) and 40°C (104°F) at the installation
site with fluctuations of less than 10°C (50°F) per hour.
There must be a two-inch clearance for each side and the back of the device for adequate
ventilation.
Install Cabletron Systems WAN Port Interface Modules (WPIMs) and the CSX-COMP/ENCR
modules (when necessary) into the CSX200 before proceeding with the installation of your
CSX200. Refer to the Installing a WPIM and COMP/ENCR Module Installation sections
within this chapter for installation instructions.
!
CAUTION
The WPIM, CSX200-COMP/ENCR, and the CSX200 are sensitive to static
discharges. Use a grounding strap and observe all static precautions during
installation. Failure to do so could result in damage to the WPIM, CSX200-COMP/
ENCR and the CSX200.