INSTALLATION REQUIREMENTS AND SPECIFICATIONS
Page 2-4
2.3.2 Power Supply Requirements
M8PSM
The M8PSM power supply senses and automatically adapts to the
input voltage and frequency.
Input Frequency:
50/60 Hz
Input Voltages & Current:
100 to 125 Vac, 5A
200 to 250 Vac, 2.5A
Fuses:
One 250 V, 10 Amp fuse
(not
user serviceable)
BTUs/Hour: 1575.2
The mains cord used with this equipment must be a two-conductor-
plus-ground type with minimum 1 mm
2
conductors and must
incorporate a standard IEC appliance coupler on one end and a mains
Table 2-1. Output Voltage Specifications: M8PSM
Output
Voltage
(Vdc)
Minimum
Load
(amps)
Maximum
Load
(amps)
Maximum
Power
(watts)
+5 (±5%) 3 40 200
+12 (±5%) 0 5 60
-5 (±5%) 0 2 10
-9 (±5%) 0 11 99
The maximum power out of each M8PSM power supply
will not exceed 300 watts.
NOTE