Setup guide

INSTALLATION REQUIREMENTS AND SPECIFICATIONS
Page 2-6
The mains cord used with this equipment must be a two-conductor-
plus-ground type with minimum 1 mm
2
conductors and must
incorporate a standard IEC appliance coupler on one end and a mains
plug on the other end which is suitable for the use and application of
the product and that is approved for use in the country of application.
These units are intended for indoor use only.
M8PSM-EDC
The M8PSM-EDC features polarity detection on the DC input; if the
unit has been incorrectly installed and polarity is reversed, an
internal buzzer will sound alerting the user to take corrective action.
Input Voltages & Current: 36 to 72 Vdc, 17A
Fuses: One 250 V, 20 Amp fuse (not
user serviceable)
BTUs/Hour: 2362.8
Table 2-3. Output Voltage Specifications: M8PSM-EDC
Output
Voltage
(Vdc)
Minimum
Load
(amps)
Maximum
Load
(amps)
Maximum
Power
(watts)
+5 (±5%) 3 60 300
+12 (±5%) 0 10 120
-5 (±5%) 0 2 10
-9 (±5%) 0 15 135
The maximum power out of each M8PSM-EDC power
supply will not exceed 450 watts.
NOTE