7.6 CONNECTING/DISCONNECTING A UPS
The EMM-E6 provides the option of connecting to an Uninterruptible
Power Supply (UPS) using Local Management.
To enable the UPS connection using EMM-E6/LM:
1. Use the arrow keys to highlight the COM 1 Application: field.
2. Press the Return key until “UPS” appears in the field. This field
toggles between “OFFLINE”, which is the default value, “UPS”, and
“SLIP”.
3. Use the arrow keys to highlight the COM 1 Baud Rate field.
4. Press the Return key until “2400 Connect?” appears in the field.
5. Use the arrow keys to highlight Connect?.
6. Press the Return key. The request “Y/N:_” appears.
7. Enter Y if you want to connect a UPS, or N if you do not want a UPS
connection. Entering a Y response connects the EMM-E6 to the UPS
and “-- Active --” appears in the Connect? field.
8. Press the Return key.
To disable the UPS connection using EMM-E6/LM:
1. Use the arrow keys to highlight -- Active -- in the COM 1 field.
2. Press the Return key. The option “Disconnect? Y/N:” appears.
3. Enter Y if you want to disconnect a UPS, or N if you want to remain
connected. Entering a Y response disconnects the EMM-E6 from the
UPS. “-N/A-” will appear in the Baud Rate field, and the COM1
Application field changes to “OFFLINE”.
4. Press the Return key.